Specifications – Kenmore IntelliSoft 350 Series 625.383560 User Manual
Page 33
33
Specifications
FIG. 49
Questions? Call The Kenmore Water Line 1-800-426-9345
A
B
C
D
E
F
Inches
CM
A
Salt Tank Height
40-1/4
102.2
B
Resin Tank Diameter
(nominal)
9
22.9
C
Resin Tank Height (nominal)
40
101.6
D
Inlet-Outlet Height
41-1/2
105.4
E
Overall Height
47-3/4
121.3
F
1
Length
19-3/4
50.2
F
2
Width
16-1/2
41.9
-
Distance between inlet-outlet
centerlines
3-3/8
8.6
BYPASS VALVES
MODEL 38356 TIMER CODE S 32
MODEL 39356 TIMER CODE S 33
SINGLE BYPASS
3 VALVE BYPASS
Bypass valve(s) should always remain in soft water
service position. Position in “bypass” only if needed for
softener repairs.
pull stem
outward for
service
FOR SERVICE
close bypass valve
open inlet & outlet valves
FOR BYPASS
open bypass
close inlet & outlet
push
inward for
bypass
Inlet
valve
gpm = gallons per minute gpg = grains per gallon
psi = pounds per square inch ppm = parts per million
* Capacity to remove clear water iron is substantiated by WQA test data. State of Wisconsin requires additional treatment if water supply contains
greater than 5 ppm clear water iron.
Outlet
valve
Bypass
valve
WATER SUPPLY TO WATER SOFTENER
MODEL 38356
MODEL 39356
Minimum water system flow (gpm)
3
Minimum-maximum water pressure (psi)
20 - 125
20 - 125
Minimum-maximum water temperature (°F)
40 - 120
40 - 120
Maximum water hardness (gpg)
100
100
Maximum “clear water” iron (ppm)*
9
9
SALT FOR WATER SOFTENER
Type of salt needed
nugget
Alternate type of salt
pure, evaporated, compacted
water softener salt
pure, evaporated, compacted