Faceplate Timer Features

FIG. 38

RECHARGE TIME REMAINING AND VALVE
POSITION INDICATORS

One of the valve position indicators (Serv, Fill, Brine,
Bkwsh, Rinse) is displayed while the softener is recharg-
ing. RECHARGE flashes in the display and, beginning
with Brine, the minutes of recharge remaining before
return to service appears in place of the present time.
When the valve is moving from one cycle to another, both
position indicators are flashing. See Fig. 38.

PROGRAM MEMORY

If electrical power to the softener goes off, the time dis-
play is blank but the face plate timer keeps the correct
time for about 6 hours. When electrical power comes on
again, you have to reset the present time only if the dis-
play is flashing. The HARDNESS and RECHARGE TIME
never require resetting unless a change is desired. Even
if the timer is incorrect after a long power outage, the sof-
tener works as it should to keep your water soft.
However, regenerations may occur at the wrong time of
day until you reset the timer to the correct time of day.

ERROR CODE

An error code could appear in the face plate display if a
problem occurs in the softener electronics. Turn to the
Troubleshooting section to resolve the problem and/or call
the Kenmore Water Line number listed below.

KENMORE’S ULTRA CLEANSING FEATURE

The ultra cleansing feature keeps larger particles of sedi-
ment from entering the home’s plumbing system. As
water passes through the softener, the larger sediment
particles are collected in the integrated basket and then
rinsed to the drain before each regeneration. The ultra
cleansing feature provides added protection for water
using appliances by reducing the chance of larger parti-
cles entering the various products valves and screens. An
extra backwash will be preprogrammed into the electron-
ics by the factory. This extra backwash will help keep the
ultra cleansing feature screen clean.

Important: The ultra cleansing feature is not intended
to replace pretreatment filtration. For problem water
applications, additional sediment filtration is recom-
mended.

Sears offers a full line of dedicated sediment filtration
products.

8
7
6
5
4
3
2
1

RECHARGE

TIME REMAINING

OFF SERV

FILL
BRINE

BKWSH
RINSE

MIN

Valve Position

Indicators

Recharge Time

Remaining

Ultra Cleansing Screen

Top Distributor

FIG. 39

FIG. 40

Questions? Call The Kenmore Water Line 1-800-426-9345

This manual is related to the following products: