beautypg.com

Leak test, House main water shutoff valves, Single bypass – Kenmore IntelliSoft 350 Series 625.383560 User Manual

Page 15: Valve bypass

background image

15

Leak Test

LEAK TEST

To check for leaks, complete the following steps:

CAUTION: To avoid water or air pressure dam-
age to softener inner parts, and to flush pipe
chips or other residue from the water pipes, be
sure to do the following steps exactly as
instructed.

1. Fully open two cold, soft water faucets near the

softener.

2. Look at the pictures in Fig. 18 and 19 to deter-

mine your kind of bypass valve(s). Place bypass
valve(s) in “bypass” position. On a single valve,
slide the stem inward to bypass. On a three (3)
valve system, close the inlet and outlet valves and
open the bypass valve.

3. Fully open the house main water pipe shutoff

valve. Observe steady water flow from both open
faucets.

4. Place bypass valve(s) in SERVICE EXACTLY as

follows: Keep soft water faucets open.
a. Single Bypass Valve: Slowly, slide pull the
valve stem outward toward service, pausing sev-
eral times to allow the softener to pressurize slow-
ly.
b. Three Valve Bypass: Fully close the bypass
valve and open the outlet valve. Slowly, open the
inlet valve, pausing several times to allow the sof-
tener to pressurize slowly.

5. After about three minutes, open a hot water

faucet for about one minute, or until all air is
expelled, then close.

6. Close both cold water faucets.
7. Check your plumbing work for leaks and fix right

away if any are found. Be sure to observe previ-
ous caution notes.

NOTE: If this procedure is performed on a new
softener, water coming from the taps may initial-
ly be discolored. This normally occurs the first
time water runs through the resin bed. The dis-
colored water is not harmful, and the discol-
oration will not last more than a few minutes.

HOUSE MAIN WATER

SHUTOFF VALVES

Shutoff Valve

Water
Meter

Shutoff Valve

Pressure Tank

Well Pump

SINGLE BYPASS

Pull Stem Outward

For Service

Push Inward

For Bypass

VALVE BYPASS

FOR SERVICE

Close bypass valve.

Open inlet & outlet

valves.

FOR BYPASS

Open bypass valve.

Close inlet & outlet

valves.

Outlet

Valve

Bypass
Valve

Inlet

Valve

FIG. 18

FIG. 19

FIG. 17

Questions? Call The Kenmore Water Line 1-800-426-9345

Note: Stem may be installed
in either direction. The end
with writing should be pulled
out for service position.