beautypg.com

Kenmore 153.331572 User Manual

Page 9

background image

9

TYPICAL INSTALLATION

GET TO KNOW YOUR WATER HEATER - GAS MODELS

A Vent

Pipe

B Draft

Hood

C Anode (Not Shown)
D Hot Water Outlet
E Insulation
F Gas Supply Piping
G Manual Gas Shut-off Valve
H Ground Joint Union

I Drip Leg (Sediment Trap)

* INSTALL IN ACCORDANCE
WITH LOCAL CODES.

* DRIP LEG AS REQUIRED
BY LOCAL CODES.

FIGURE 1.

J Inner

Door

K Outer

Door

L Union
M Inlet Water Shut-off Valve
N Cold Water Inlet
O Inlet Dip Tube
P Temperature-Pressure Relief Valve
Q Rating

Plate

R Flue Baffl e

S Thermostat
T Drain

Valve

U Pilot and Main Burner
V

Flue

W Drain Pan
X Piezo Igniter
Y Base-Ring

Filter

* ALL PIPING MATERIALS TO BE
SUPPLIED BY CUSTOMERS.

TO VENT

TERMINATION ON

ROOF

A

B

D

F

G

H

I

W

V

U

T

S

O

R

J

K

Q

VACUUM RELIEF

VALVE

*INSTALL PER

LOCAL CODES

INSTALL THERMAL EXPANSION

TANK OR DEVICE IF WATER

HEATER IS INSTALLED IN A

CLOSED WATER SYSTEM

M

N

L

E

P

X

Y

MANIFOLD TUBE

IGNITER WIRE

MAIN BURNER

PILOT TUBE

THERMOCOUPLE

IGNITER ROD

(U) MANIFOLD/BURNER ASSEMBLY

MANIFOLD DOOR

DISCHARGE PIPE

(DO NOT CAP OR PLUG.)

6” MAXIMUM

AIR GAP

FLOOR DRAIN

GAS CONTROL KNOB

WATER TEMPERATURE DIAL

(ADJUSTING DIAL)

TOP VIEW

“OFF”

POSITION

“PILOT”

POSITION

“ON”

POSITION

(S) GAS CONTROL VALVE/

THERMOSTAT: WHITE-RODGERS