4. The maximum wire run distance between the first and last device in an inter-

connect system is 1000 ft.

5. Figure 1 illustrates interconnection wiring. Improper connection will result in

damage to the strobe light or alarms, failure to operate, or a shock hazard.

6. Make certain that all devices in the interconnect system are wired to a contin-

uous (non-switched, non-GFI or GCFI protected) power line.

FIGURE 1: INTERCONNECT WIRING DIAGRAM FOR SL177i.

WIRE ON STROBE LIGHT HARNESS CONNECTED TO:
BLACK . . . . . . . . . .HOT SIDE OF AC LINE
WHITE . . . . . . . . . .NEUTRAL AC LINE
RED . . . . . . . . . . . .INTERCONNECT LINES (RED WIRES) OF THE OTHER UNITS

IN THE MULTIPLE STATION SET UP

N

L

WIRE NUT
OR
EQUIVALENT

WHITE

BLACK

RED

WHITE

RED

BLACK

WHITE

WHITE

RED

RED

BLACK

BLACK

FUSE OR CIRCUIT BREAKER

SMOKE ALARM

STROBE LIGHT

HEAT ALARM

CO ALARM

FIGURE 1

BLACK

WIRE NUT OR
EQUIVALENT

WHITE

FUSE OR CIRCUIT BREAKER

SWITCHING DEVICE USED
TO CONTROL THE
OPERATION OF THE
SL177 STROBE LIGHT

FIGURE 2