beautypg.com

Process ra-4 cycle—average utilization, Process ra-4 cycle—high utilization – Kodak C-41RA User Manual

Page 5

background image

Choosing the Right Chemicals for Your Minilab

J-36

5

Process RA-4 Cycle—Average Utilization

This cycle is appropriate for processors with average
utilization—i.e., a developer tank turnover occurs at least
once every four weeks.

Solution/

Step

Time

*

min:sec

* Immersion time plus crossover time to the next tank. For best results,

use the recommended times with crossover times of 6 seconds or less.

Temperature

°C (°F)

Starting-Point

Replenishment

Rate

mL/m

2

(mL/ft

2

)

EKTACOLOR
PRIME SP
Developer
Replenisher

or
EKTACOLOR
PRIME
Developer
Replenisher

† This developer may not yet be available in your country. If not, use

EKTACOLOR PRIME Developer Replenisher in a processor with
average utilization.

0:45

37.8

±

0.3

(100.0

±

0.5)

108 (10)

161 (15)

EKTACOLOR
PRIME
Bleach-Fix
Replenisher

0:45

30 to 36

(86 to 97)

108 (10)

EKTACOLOR
PRIME
Stabilizer and
Replenisher

‡ Use four countercurrent-flow stabilizer tanks with equal times in all

tanks (0:23 in each tank). With three countercurrent-flow tanks, use a
replenishment rate of 495 mL/m

2

(46 mL/ft

2

); with two

countercurrent-flow tanks, use 970 mL/m

2

(90 mL/ft

2

).

If your minilab uses a countercurrent-flow wash instead of a
stabilizer, use a wash-water temperature of 30 to 40°C (86 to 104°F).
For wash times of 1:30 or longer, the wash-flow rate should be
between 2160 and 10,800 mL/m

2

(200 and 1000 mL/ft

2

). The actual

rate depends on the number of tanks and the wash time (see KODAK
Publication No. Z-100, Using KODAK Chemicals in Minilabs, or Z-130,
Using KODAK EKTACOLOR RA Chemicals).

1:30

30 to 37

(86 to 99)

248 (23)

Dry

As

needed

Not over
96 (205)

Process RA-4 Cycle—High Utilization

This cycle is appropriate for processors with high
utilization—i.e., a developer tank turnover occurs at least
once every two weeks.

Solution/

Step

Time

*

min:sec

* Immersion time plus crossover time to the next tank. For best results,

use the recommended times with crossover times of 6 seconds or less.

Temperature

°C (°F)

Starting-Point

Replenishment

Rate

mL/m

2

(mL/ft

2

)

EKTACOLOR
PRIME SP
Developer
Replenisher

or
EKTACOLOR
PRIME
Developer
Replenisher
LORR

† This developer may not yet be available in your country. If not, use

EKTACOLOR PRIME Developer Replenisher LORR in a processor
with high utilization.

0:45

37.0

±

0.3

(100.0

±

0.5)

108 (10)

EKTACOLOR
RA 100
Bleach-Fix
and
Replenisher

‡ This product will be renamed KODAK EKTACOLOR PRIME

Bleach-Fix Replenisher LORR.

0:45

30 to 36

(86 to 97)

54 (5)

EKTACOLOR
PRIME
Stabilizer and
Replenisher

§

§ Use four countercurrent-flow stabilizer tanks with equal times in all

tanks (0:23 in each tank). With three countercurrent-flow tanks, use a
replenishment rate of 495 mL/m

2

(46 mL/ft

2

); with two

countercurrent-flow tanks, use 970 mL/m

2

(90 mL/ft

2

).

If your minilab uses a countercurrent-flow wash instead of a
stabilizer, use a wash-water temperature of 30 to 40°C (86 to 104°F).
For wash times of 1:30 or longer, the wash-flow rate should be between
2160 and 10,800 mL/m

2

(200 and 1000 mL/ft

2

). The actual rate

depends on the number of tanks and the wash time (see KODAK
Publication No. Z-100, Using KODAK Chemicals in Minilabs, or Z-130,
Using KODAK EKTACOLOR RA Chemicals).

1:30

30 to 37

(86 to 99)

248 (23)

Dry

As

needed

Not over
96 (205)