Choosing the Right Chemicals for Your Minilab

J-36

Process C-41RA

This film process cycle is the shortest of the Process C-41
cycles, and the one most commonly used in minilabs. You
must use KODAK FLEXICOLOR RA Bleach Replenisher
NR and KODAK FLEXICOLOR RA Fixer and
Replenisher in this cycle.

Process C-41RA requires special equipment that

accommodates the shorter solution times, and the processor
must provide higher agitation in the bleach, fixer, and final
rinse. Check with your minilab manufacturer to determine if
your processor meets Process C-41RA specifications.

Although Process C-41RA is intended to be a washless

cycle, you can use it with a processor that includes a final
wash if it meets the time and agitation requirements.

Process C-41RA Cycle

Solution/Step

Time

*

min:sec

* Immersion time plus crossover time to the next tank. Bleach, fixer, and

final rinse times are minimums; longer times are acceptable.

Temperature

°C (°F)

FLEXICOLOR
Developer
Replenisher LORR

3:15

37.8

±

0.15

(100.0

±

0.25)

FLEXICOLOR RA
Bleach Replenisher
NR

† Use only KODAK FLEXICOLOR RA Bleach Replenisher NR. Your

equipment must provide the higher agitation required for this solution.

1:00

38

±

3

(100

±

5)

FLEXICOLOR RA
Fixer and
Replenisher

‡ Use only KODAK FLEXICOLOR RA Fixer and Replenisher. Use two

countercurrent-flow fixer tanks with equal times in both tanks (0:45 to
1:00 in each tank). Your equipment must provide the higher agitation
required for this solution.

1:30 to 2:00

38

±

3

(100

±

5)

FLEXICOLOR
Final Rinse and
Replenisher

§

§ Use three countercurrent-flow final rinse tanks with equal times in

all tanks (0:20). Your equipment must provide the higher agitation
required for this solution. Replenish the third final rinse tank at
40 mL/135-24 roll (36 mL/m). If your processor has two
countercurrent-flow final rinse tanks followed by a single tank,
replenish the second countercurrent tank at 40 mL/135-24 roll
(36 mL/m) and the single tank at 20 mL/135-24 roll (18 mL/m). For
minilabs with a final wash after the fixer, use a wash time of 1:40 and
reduce the final rinse time to 40 seconds. Use a wash rate of
1250 mL/135-24 roll (330 mL/ft) for a two-stage countercurrent-flow
wash. Double this rate for a single wash. Use a final rinse
replenishment rate of 33 mL/135-24 roll.

1:00

38

±

3

(100

±

5)

Dry

As needed

40 to 68

(104 to 155)

Starting-Point Replenishment Rates—
Process C-41RA

Process C-41B

The primary feature of this cycle is that it is shorter than
the standard Process C-41 cycle. It eliminates both washes
and uses a shorter fixer time. Most minilabs that use
Process C-41B use the washless version. However, if your
minilab includes a final wash, see footnote

§

, below.

Process C-41B Cycle

Solution

Starting-Point

Replenishment Rate

mL/135-24 Roll

(mL/m)

mL/25-Exp

ADVANTIX Film

(mL/m)

*

* These rates are averages based on an estimated film-speed mix in

25-exposure rolls of KODAK ADVANTIX Films.

FLEXICOLOR Developer
Replenisher LORR

19 (17)

11.1 (10.2)

FLEXICOLOR RA
Bleach Replenisher NR

5 (4.5)

3.4 (3.1)

FLEXICOLOR RA Fixer
and Replenisher

35 (32)

24 (22)

FLEXICOLOR
Final Rinse and
Replenisher

40 (36)

27 (25)

Solution/Step

Time

*

min:sec

* Immersion time plus crossover time to the next tank. Bleach, fixer, and

final rinse times are minimums; longer times are acceptable.

Temperature

°C (°F)

FLEXICOLOR Developer
Replenisher LORR

3:15

37.8

±

0.15

(100.0

±

0.25)

FLEXICOLOR Bleach III
NR Replenisher

3:00 to 4:20

38

±

3

(100

±

5)

FLEXICOLOR Fixer and
Replenisher

† Use two countercurrent-flow fixer tanks with equal times in both tanks

(2:00 to 2:10 in each tank).

4:00 to 4:20

38

±

3

(100

±

5)

FLEXICOLOR Final Rinse
and Replenisher

‡,§

‡ Use three countercurrent-flow final rinse tanks with equal times in all

tanks (0:47 in each tank).

§ If your minilab uses a final wash, also install a wash between the fixer

and final rinse with a wash time of 1:40. Reduce the final rinse time
to 40 seconds, and use a replenishment rate of 35 mL/135-24 roll
(32 mL/m). Use a wash-flow rate of 1250 mL/135-25 roll (1080 mL/m)
for a two-stage countercurrent wash or 2500 mL/135-24 roll
(2160 mL/m) for a single-stage wash.

2:20

38

±

3

(100

±

5)

Dry

As needed

40 to 68

(104 to 155)