beautypg.com

Replacing the mechanism assembly – Kodak Ektagraphic III PAINTED and NON-PAINTED PROJECTORS J-E PLUS User Manual

Page 13

background image

Replacements and Installations

SM4530-1 – 30APR96

13

Replacing the MECHANISM ASSEMBLY

Warning

Dangerous Voltage

[1] Disconnect the main power.

[2] Do the replacement procedure for the LOWER

HOUSING ASSEMBLY.

[3] Cut and remove the necessary WIRE TIES.

[4] Disconnect the 2 wires from the CYCLE

SOLENOID on the SMALL CIRCUIT BOARD.

[5] Pull the SMALL CIRCUIT BOARD up.

[6] Disconnect all wires connected to the

MECHANISM ASSEMBLY:

• 1 yellow wire from CYCLE SWITCH

• 1 orange wire from WIRE NUT

• 1 green wire from POWER CORD

• 2 green ground wires from the lower

MECHANISM ASSEMBLY

[7] Remove the FOCUS KNOB from the FRONT

PANEL.

Important

For Auto-Focus models only, disconnect the short, gray
wire connected to the AUTO-FOCUS DEFEAT
SWITCH.

[8] Remove the 3

Torx SCREWS from the LENS

MOUNT ASSEMBLY.

[9] Lift and move the LENS MOUNT ASSEMBLY up.

[10] Do the replacement procedure for the MOTOR.

[11] Remove the 3

Torx SCREWS from the

MECHANISM ASSEMBLY.

[12] Loosen the SCREW on the STABILIZER WALL

approximately half way.

[13] Remove the SCREW from the DARK SHUTTER

SWITCH and remove the SWITCH.

Caution

There might be a bind between the SELECT LEVER
and the SELECT BUTTON when removing the
MECHANISM ASSEMBLY. Do not use force; this
might cause damage to the SELECT BUTTON.

[14] Remove the MECHANISM ASSEMBLY.

A091_4022CA

SWITCH

DARK
SHUTTER

ASSEMBLY

MECHANISM

(not shown)

DEFEAT SWITCH

AUTO FOCUS

FOCUS KNOB

A091_4022CCA

SCREW

MOUNT

LENS

SCREW (3)

SCREW