beautypg.com

Instructions for the installer, Adapting to different types of gas – Smeg PVA96 User Manual

Page 9

background image

Instructions for the installer

11

4. ADAPTING TO DIFFERENT TYPES OF GAS

Before any intervention, disconnect the power supply of the device.

The hob has been adjusted for natural gas at a pressure of 1.0kPa.
If used with other types of gas, you have to replace the nozzles and
regulate the primary air to the burners. Then regulate the minimum flame
on the gas taps. For nozzle replacement and burner adjustment you must
raise the hob as described in the following paragraph.


4.1 Removing the top

1. Slide out the grids, and remove all burner caps, flame cap crowns

and burners.

2. Remove the screws and nuts A which hold burner supports in place.
3. Remove

plates

B.

4. Lift up top C with the aid of a screwdriver and remove it from its seat.
5. Replace the burner nozzles according to the specifications in the

reference gas table.

6. Adjust primary air as described in paragraph “4.2 Regulation for

LPG”.