24

Barracuda ES.2 FC Product Manual, Rev. B

three-quarters to maximum track.

General DC power requirement notes.

1.

Minimum current loading for each supply voltage is not less than 1.2% of the maximum operating current
shown.

2.

The +5V and +12V supplies should employ separate ground returns.

3.

Where power is provided to multiple drives from a common supply, careful consideration for individual
drive power requirements should be noted. Where multiple units are powered on simultaneously, the peak
starting current must be available to each device.

4.

Parameters, other than spindle start, are measured after a 10-minute warm up.

5.

No terminator power.

6.2.1

Conducted noise immunity

Noise is specified as a periodic and random distribution of frequencies covering a band from DC to 10 MHz.
Maximum allowed noise values given below are peak-to-peak measurements and apply at the drive power
connector.

6.2.2

Power sequencing

The drive does not require power sequencing. The drive protects against inadvertent writing during power-up
and down.

+5 V =

250 mV pp from 0 to 100 kHz to 20 MHz.

+12 V =

800 mV pp from 100 Hz to 8 KHz.

450 mV pp from 8 KHz to 20 KHz.

250 mV pp from 20 KHz to 5 MHz.

This manual is related to the following products: