6

TROUbLESHOOTING

9.

PRObLEM: ALARM IS ON

REASON

SOLUTION

Display shows SC. Device has a short

circuit or demands too much surge

power.

Cycle inverter power OFF and ON.
If problem persists, use a larger inverter

or a smaller device
Remove defective device.
Call 1-800-SEARS-64 (1-800-732-7764)

for troubleshooting assistance.

Display shows Lob. 12 Volt battery is

too low.

Recharge/replace low battery.

Display shows Voltage in between

10.5 and 11.0 Volts.

12 Volt battery is low.
Recharge/replace low battery.
Inverter will automatically shut off after

battery voltage reaches 10.5 volts.

Display shows Hib. DC Voltage in is

too high.

If in a vehicle, repair/replace the alterna-

tor or charging system.
Use a properly sized and rated 12 Volt

battery.
If input voltage returns to 15 volts or less,

the inverter will automatically restart.

Display shows HiP. Device demands

more than 750 Watts continuous

power.

Cycle inverter power OFF and ON.
If problem persists, use a larger inverter

or a smaller device.

Display shows HoT. Inverter is too hot. Increase ventilation to inverter.

Move inverter to a cooler area.

Reduce the power consumption of the

device.

Inverter will automatically reset after

cooling.

PRObLEM: INVERTER DOES NOT TURN ON

REASON

SOLUTION

Poor contact at terminals.

Unplug and reinsert Power Inverter 750.

Fuse is blown.

A blown fuse is usually caused by re-

verse polarity or a short circuit within the

inverter. The fuse is not user replaceable.

Inverter may be defective.

Call 1-800-SEARS-64 (1-800-732-7764)

for troubleshooting assistance.