Fig w, Fig n fig o – Siemens 5551 User Manual
Page 24
K
L
Z
L2
L1
M5
M2
M1
M3
M4
M5
Y
M
Fig N
Fig O
Fig W
Screw in the new main burner tip, pushing the
burner tip casing in the opposite direction with a
13 mm spanner.
Loosen the holding screw Fig. L1 and set the
regulating bushing of the air flow to the value
indicated in the burner tip table.-Z-
Tighten the locking screw.
7 - Changing the inner flame burner tip.
Using an 8 mm spanner, unscrew the connector
Fig. M3 from the threaded component Fig. M2. To
do this, hold the threaded component firmly in the
Fig. N.
Then, using a 12 mm spanner, unscrew the
threaded component Fig. M2 from the component
Fig. M1, holding the latter firmly in the opposite
Unscrew the burner tip Fig. M4 from component
Fig. M2 and replace it with the appropriate burner
tip as indicated in the burner tip table, and adjust
the regulating bushing of the air flow M5 in line with
the value indicated in the burner tip table. -Y-
* If the appliance is not firmly fixed or the clipping
system is too rigid, it may cause the entire appliance
to lift up. In this case follow this procedure:
1) Loosen the fixing clips of the appliance to
the kitchen unit.
2) Loosen the main gas connection and take
the appliance out of its seating.
3) Apply the disassembly lever 483196 as
shown in Fig. W.
direction with a 12 mm spanner. See Fig. O.
C) Reduced consumption adjustment of the
opposite direction using a 12 mm spanner. See
cooktop burner taps.
1 - Set the taps to the minimum setting.
2 - Remove the control knobs from the taps. Fig. 6.
22
Fig. M.
IMPORTANT INFORMATION