63
GSM M1 Module, English: A24859-N4000-A100-1-7677
gsm-m1-e.fm
Technical reference section
6.3.96
Although you enter values for S-registers as decimal numbers, like all other values that
are stored in PCs they are stored in the registers in binary format:
The value of the register is obtained by adding together the values of all enabled bits.
In the example, all bits are enabled ("1") and the result is the number 255. Since all bits
can also be disabled ("0"), a total of 256 statuses can be stored in these 8 bit positions.
This means that more than one parameter can be stored in one register.
Example:
Decimal
Binary
3
00000011
43
00101011
100
01100100
If a command applies only to bits 3, 4 and 5 of an S-registers, up to 8 different statuses
can be defined:
Binary and decimal values in S-registers
Bit #
7
6
5
4
3
2
1
0
Binary
1
1
1
1
1
1
1
1
Decimal
128
64
32
16
8
4
2
1
Option
Bit 5
Bit 4
Bit 3
Dec.
0
0
0
0
0
1
0
0
1
8
2
0
1
0
16
3
0
1
1
24
4
1
0
0
32
5
1
0
1
40
6
1
1
0
48
7
1
1
1
56