26.2.96

Even if your PC is set, for example, to 19200 baud, the maximum GSM rate that can
be used is 9600 bit/s. A higher setting causes the GSM module to receive more data
from the PC than it can transfer to the GSM network. In order to prevent a data over-
flow, it must be able to interrupt the data flow from the PC. This is accomplished by
means of the RTS/CTS hardware data flow control, which switches over the COM in-
terface so as to interrupt the RTS (computer) and CTS (GSM module) control lines.

The GSM module is equipped with a 128-byte nonvolatile RAM in which the values of
the modifiable S-registers and other values are stored. This section describes the val-
ues, how to store them and how to use them.

AT&Dn - Data Terminal Ready (DTR) options

AT&Dn

[n=0..3]

Option

Result

AT&D0

The GSM module ignores the status of the DTR control line connected
to the COM interface.

AT&D1

When the DTR line switches from ON to OFF, the GSM module changes
to command mode. The existing connection to the distant station is not
cleared down.

AT&D2

When the DTR line switches from ON to OFF, the GSM module sets up
a connection to the distant station, switches to command mode and
deactivates auto-answer mode. Auto-answer can be reactivated by
resetting DTR to ON.

AT&D3

The transition of DTR to OFF has the same effect as an AT&F command,
i.e. the factory configuration is loaded. An existing connection to the dis-
tant station is cleared down.

Data flow control