7 Web Diagnostics
B3L−39
CP 343-1 Lean for Industrial Ethernet / Manual Part B3L
Release 03/2007
C79000-G8976-C198-04
7.2.4
Diagnostic Buffer
This table lists all the events in the chronological order in which they were
received. The latest entry is at the start and the oldest entry at the end of the table.
By clicking on the various tabs above the table, you can select the individual
modules in the rack.
Parameter
Function
Events
Number
Consecutive number of the entry
Time
Time of the entry
Note
If the module has synchronized itself with a time server, the current time is
displayed. Otherwise the time since the last restart is displayed.
Date
Date of the entry if the module is synchronized. Otherwise the default time of the
module (01.01.1994) or the day of the last restart is displayed.
Event
Displays the diagnostic buffer entry (entries only in English)
Details: “no. of the event”
Event ID
Event ID of the diagnostic buffer entry
Text of the event entry