Origin offset, Dome reset, System information – Speco Technologies CVC-927PTZ User Manual
Page 37

Erase all stored data from the Flash-ROM of the selected dome camera. You will be asked to 
enter Yes or No. If you intend to erase all data then press the MENU key, otherwise press the 
ESC
key to exit without erasing. The erased data includes all stored data (titles, presets, and
tours….) except origin offset. 
The offset value is still valid after all data is erased. The offset value can be zeroed only with 
default set of Offset origin menu. 
 
CAUTION: All the data in the selected dome camera will be lost unless you download the
data into a safe place. (Refer to Download/ Upload data function in the 
Keyboard Configuration utility.) Data from the selected dome camera can be 
stored in the keyboard controller temporarily. If you want to save the data of all 
installed dome cameras, you need a special I/O interface and software for PC. 
• ORIGIN OFFSET
 
This feature is useful to align a new dome camera exactly the same as the previously installed 
dome camera. 
Dome camera’s origin set and all data initialize option do not override offset values. Only the 
default set option in this menu will set the offset value to zero. This can be used to avoid ceiling 
obstructions. 
 
• DOME RESET
 
This feature is used to re-calibrate the orientation of a selected dome camera. Origin offset value 
is not affected by this function. (Offset is still valid after origin set) 
 
• SYSTEM INFORMATION
 
 
SYSTEM INFORMATION
CAMERA TYPE : XXXXXXX 
H/W VERSION : V1.0 
ROM VERSION : V1.0 
PROTOCOL : F2E 
BUADRATE : 9600BPS 
EXIT(ESC TO EXIT) 
 
 
 
 
 
 
 
 
 
 
A Dome camera’s Setup menu provides essential information about the dome camera if service 
is required. When you view this screen, you can determine the camera type, ROM version. 
The information on this screen cannot be modified. 
30