7

E. PIN Code
Device uses a PIN Code to identify during connecting

and communication.
F. Role
Role is for identifying the role of the device as a master

or slave. Select Master, for DTE mode, for Data Terminal

Equipment (such as a PCs). Select Slave for DCE mode,

for Data Communication Equipment (such as a Modem).
G. Discoverable
Allows or denies the device detection by other Bluetooth

devices.
H. Baud Rate
The baud rate range is 1200 bps-15.2K bps depending on

transmission distance and environment. Normally, the

default baud rate is set to 9600 bps N, 8 ,1.
I. Handshake (DSR/DTR)
The handshake is set at Disable.
J. Stop Bit
The stop bit is set at One Bit.
K. Parity
Parity is set at None.