H

EAVY

D

UTY

C

OUNTERLINE

I

NSTALLATION

Step 3: Attach Restraint for Appliances Mounted on Casters

NOTICE

For an appliance equipped with casters, (1) the installation shall be made with a connector that
complies with the Standard for Connectors for Movable Gas Appliances, ANSI Z21.69 or Connectors
for Moveable Gas Appliances, CAN/CGA-6.16,
and a quick-disconnect device that complies with the
Standard for Quick-Disconnect Devices for Use With Gas Fuel, ANSI Z21.41, or Quick Disconnect
Devices for Use with Gas Fuel, CAN1-6.9,
(2) adequate means must be provided to limit the
movement of the appliance without depending on the connector and the quick-disconnect device or
its associated piping to limit the appliance movement and (3) the restraining means should be
attached to a frame member on the back of the unit.

INSTALLATION

!

WARNING

To avoid accidental gas disconnection and potential explosion:

If disconnection of this restraint is necessary to move the appliance for cleaning, etc., reconnect it
when the appliance is moved to its originally installed position.

Appliances mounted on a stand with casters or other movable surface must be equipped with a restraining
means to prevent accidental stress on the flexible gas connection.

1. Secure the restraining-device bracket (item “B” in the following illustration) to a wall stud located as

close as possible to the appliance connector inlet and outlet connections. Use four #12 screws (items
“C”) and plastic anchors (items “A”) if necessary.

Figure 12

Note: Kit can be purchased from Southbend (part number 1176867).