MODEL
INDOOR UNIT
OUTDOOR UNIT
ITEMS
AY-XP9FR
AE-X9FR
Cooling capacity(Min. > Max.)
kW
2.64 (0.9 - 3.0)
Heating capacity(Min. > Max.)
kW
3.1 (0.9 - 4.8)
Moisture removal(at cooling)
Liters/h
Electrical data
Phase
Single
Rated frequency
Hz
50
Rated voltage
V
230
Rated current
✩
(Min - Max.)
Cool
A
3.7 (1.0 - 4.8)
Heat
A
3.5 (0.9 - 6.1)
Rated input
✩
(Min - Max.)
Cool
W
780 (200 - 960)
Heat
W
730 (160 - 1400)
Power factor
✩
Cool
%
92
Heat
%
91
Compressor
Type
Hermetically sealed rotary type
Model
DA89X1F-23F
Oil charge
370cc (VG74)
Refrigerant system
Evaporator
Louver Fin and Grooved tube type
Condenser
Corrugate Fin and Grooved tube type
Control
Expansion valve
Refrigerant (R410A)
830g
De-lce system
Micro computer controled reversed systems
Noise level
(at cooling)
High
dB(A)
39
45
Low
dB(A)
–
–
Soft
dB(A)
28
–
Fan system
Drive
Direct drive
Air flow quantity
(at cooling)
High
m3/min.
8.6
23.3
Low
m3/min.
7.3
–
Soft
m3/min.
5.5
–
Fan
Cross flow fan
Propeller fan
Connections
Refrigerant coupling
Flare type
Refrigerant tube size Gas, Liquid
3/8", 1/4"
Drain piping mm
O.D
φ18
Others
Safety device
Compressor: Thermal protector
Fan motors: Thermal fuse
Fuse, Micro computer control
Air filters
Polypropylene net (Washable)
Net dimensions
Width
mm
790
730
Height
mm
278
540
Depth
mm
198
250
Net weight
kg
10
33