beautypg.com

Ayxp7fr – Sharp AE-X7FR User Manual

Page 3

background image

AYXP7FR

1 – 2

2. AY-XP9FR – AE-X9FR

MODEL

INDOOR UNIT

OUTDOOR UNIT

ITEMS

AY-XP9FR

AE-X9FR

Cooling capacity(Min. > Max.)

kW

2.64 (0.9 - 3.0)

Heating capacity(Min. > Max.)

kW

3.1 (0.9 - 4.8)

Moisture removal(at cooling)

Liters/h

Electrical data

Phase

Single

Rated frequency

Hz

50

Rated voltage

V

230

Rated current

(Min - Max.)

Cool

A

3.7 (1.0 - 4.8)

Heat

A

3.5 (0.9 - 6.1)

Rated input

(Min - Max.)

Cool

W

780 (200 - 960)

Heat

W

730 (160 - 1400)

Power factor

Cool

%

92

Heat

%

91

Compressor

Type

Hermetically sealed rotary type

Model

DA89X1F-23F

Oil charge

370cc (VG74)

Refrigerant system

Evaporator

Louver Fin and Grooved tube type

Condenser

Corrugate Fin and Grooved tube type

Control

Expansion valve

Refrigerant (R410A)

830g

De-lce system

Micro computer controled reversed systems

Noise level
(at cooling)

High

dB(A)

39

45

Low

dB(A)

Soft

dB(A)

28

Fan system

Drive

Direct drive

Air flow quantity
(at cooling)

High

m3/min.

8.6

23.3

Low

m3/min.

7.3

Soft

m3/min.

5.5

Fan

Cross flow fan

Propeller fan

Connections

Refrigerant coupling

Flare type

Refrigerant tube size Gas, Liquid

3/8", 1/4"

Drain piping mm

O.D

φ18

Others

Safety device

Compressor: Thermal protector
Fan motors: Thermal fuse
Fuse, Micro computer control

Air filters

Polypropylene net (Washable)

Net dimensions

Width

mm

790

730

Height

mm

278

540

Depth

mm

198

250

Net weight

kg

10

33