Ayxp7fr – Sharp AE-X7FR User Manual

Page 10

background image

AYXP7FR

3 – 16

Indoor/
outdoor
units in
complete
shutdown

11

times

11

-0

Outdoor unit DC
fan

Outdoor unit DC fan
rotation error

(1)

Check connector CN3 of
the outdoor unit DC fan
motor for secure installa-
tion.

(1)

Correct the installa-
tion.

(2)

Check the outdoor unit fan
motor for proper rotation.

(2)

Replace the outdoor
unit fan motor.

(3)

Check fuse FU3.

(3)

Replace the outdoor
unit control PWB
assembly.

(4)

Outdoor unit control PWB

(4)

Replace the outdoor
unit control PWB
assembly.

Indoor/
outdoor
units in
complete
shutdown

13

times

13

-0

DC compressor

Compressor startup
error

(1)

Check the colors (red,
white, orange) of the com-
pressor cords for proper
connection. (PWB side,
compressor side)

(1)

Correct the installa-
tion.
(U: Red, V: White, W:
Orange)

-1

Compressor rota-
tion error
(120

° energizing

error)

(2)

Check if the IPM terminal
resistance values are uni-
form.

(2)

Replace the outdoor
unit control PWB
assembly.

(3)

No abnormality found in
above inspections (1) and
(2).

(3)

Replace the outdoor
unit control PWB
assembly.

(4)

No abnormality found in
above inspections (1)
through (3).

(4)

Replace the compres-
sor.

Indoor/
outdoor
units in
complete
shutdown

14

times

14

-0

Outdoor unit
PAM

PAM over voltage
error
Compressor rota-
tion error

(1)

Check the AC power sup-
ply voltage for fluctuation.

(1)

Connect stable power
supply.

(2)

No abnormality found in
above inspection (1).

(2)

Replace the outdoor
unit control PWB
assembly.

Indoor/
outdoor
units in
operation

-1

PAM clock error

(1)

Check the PAM clock for
proper input.

(1)

Replace the outdoor
unit control PWB
assembly.

Indoor
unit in
operation
Outdoor
unit in
complete
shutdown

17

-0

Wires between
units

Serial open-circuit

(1)

Check the wires between
units.

(1)

Connect stable power
supply.

(2)

Check voltage between
Nos. 1 and 2 on the
indoor/outdoor unit termi-
nal boards.

(2)

Replace the outdoor
unit control PCB
assembly.

Outdoor unit does
not turn on due to
erroneous wiring

(1)

Check the wires between
units.

(1)

Correct the wiring.

(2)

Check the outdoor unit
fuse.

(2)

Replace the fuse/out-
door unit control PCB
assembly.

(3)

Check 15-V, 13-V and 5-V
voltages on the PWB.
Check resistance between
IPM terminals.

(3)

Replace the outdoor
unit control PCB
assembly.

(4)

Check pins No. 5 and 7 of
connector CN3 of the out-
door unit fan motor for
short-circuit.

(4)

Replace the outdoor
unit fan motor.

(5)

Outdoor unit control PCB

(5)

Replace the outdoor
unit control PCB
board.

18

-0

Serial short-circuit

(1)

Check the wires between
units.

(1)

Correct the wiring.

-1

Serial erroneous wir-
ing

(1)

Check the wires between
units.

(1)

Correct the wiring.

Status of

indoor/

outdoor

units

Indication

by LED1

on out-

door unit

*2

Malfunction

No. dis-

played on

main unit

display sec-

tion *1

Content of diagnosis

Inspection location/method

Remedy

Main
cate-

gory

Sub-

cate-

gory

Main category

Sub-category