Sunrise Medical Integrated C.G. Tilt P-222SE User Manual
Page 7
930478 Rev. A
V I I . M a i n t e n a n c e & T r o u b l e s h o o t i n g T i p s
13
V I . O p e r a t i n g G u i d e
930478 Rev. A
12
A. MAINTENANCE
You should check the items on this chart at the indicated intervals. If any of the items
are loose, worn, bent or distorted, immediately have them checked and/or repaired by
your authorized Sunrise supplier. Frequent maintenance and servicing will improve per-
formance and extend wheelchair life.
NOTE– Check weekly, and use a clean, dry cloth or compressed air as needed to keep
glide bearings free of debris.
B. TROUBLESHOOTING TIPS
If you should notice your C.G. Tilt system binding up, not running in a smooth fash-
ion, or emitting an unusual noise during use, a foreign matter may have come into
contact with the glide bearings. If this occurs, use a clean, dry cloth or compressed air
to clear or, if needed, please see your authorized Sunrise supplier.
If your tilt system will not function, check to ensure the tilt lock-out sensor is seated
properly in its mount. The wires should lead out of the sensor toward the front of the
chair.
Charge Batteries
Check tires for proper inflation level
Glide bearings free of debris
Check batteries for proper electrolyte level (wet cell only)
Check plugs and connectors for proper connections
Check all moving parts for wear
Inspect all nuts, bolts and fasteners for looseness or wear
Inspect upholstery for wear
Remove and inspect motor brushes
Servicing by authorized Supplier
CHECK...
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
Quar
terly
Annually
Monthly
W
eekly
Daily
Check front mount bolts for looseness
Check actuator limit switch position
Check front mount for excessive wear
✓
✓
✓
TO OPERATE THE C.G. TILT
A. TOGGLE SWITCH ACTIVATION
1. To operate, push the toggle switch (A) forward
(to tilt back) or pull toggle backward (to return
to neutral) until tilted into the desired posi-
tion.
2. The toggle switch will return to neutral when
released and the seating system will stop moving.
B. SINGLE SWITCH ACTIVATION
1. Depress and hold single switch to tilt
back into the desired position.
2. Depress and hold single switch to return to
neutral until tilted into the desired position.
C. INTEGRAL JOYSTICK ACTIVATION (OPTIONAL)
From the “off” position:
1. Push the on/off button (A) once to turn the
chair on.
2. Push either tilt button (B or C) to activate tilt
mode.
3. Push forward on joystick (D) to tilt back.
4. Pull backward on joystick (D) to tilt forward.
5. Push either tilt button (B or C) to deactivate
and resume drive mode.
D. REMOTE JOYSTICK ACTIVATION (OPTIONAL)
From the “off” position
1. Push the on/off mode select toggle switch (A)
down once to turn the chair “on”.
2. Push the on/off mode select toggle switch (A)
up twice to move index to tilt mode (noted by
two (2) actuator lights (B)).
3. Push the joystick (C) forward to tilt backward or
backward to tilt forward.
4. Push the on/off mode select toggle switch (A)
up once to return to drive mode.
E. SPECIALTY DRIVE CONTROLS (OPTIONAL)
Please refer to your QTRONIX USCM User Instruction
Manual.
CAUTION– The power base drive lock-out feature will
activate and the chair cannot be driven if
the seating system is tilted more than 20°.