beautypg.com

3 adjusting for natural gas, 4 adjusting the primary air flow, Adjusting for natural gas – Smeg PX140 User Manual

Page 9: Adjusting the primary air flow, Instructions for the installer, 27 5.3 adjusting for natural gas

background image

Instructions for the Installer

27

5.3 Adjusting for natural gas

The appliance is tested with G20 (2H) natural gas at the pressure of 20 mbar. To return the
appliance to the condition required to use this type of gas, proceed as described in
point “

5.2 Adjusting for bottled gas” but select the nozzles and adjust the primary air

flow for natural gas, as indicated in the table below and in point “

5.4 Adjusting the

primary air flow”.

Burner

Rated heat

Capacity (kW)

Natural gas - G20 20 mbar

Nozzle diameter

Reduced heat capacity

1/100 mm

(W)

Auxiliary

1.05

73

400

Semi rapid

1.7

92

450

Rapid

3.0

123

1050

Ultra Rapid

4.2

150

1400

5.4 Adjusting the primary air flow

Refers to the gap “X” in mm.

BURNER

G20

20 mbar

G30/G31

30/37 mbar

0.5

3

Auxiliary

Semi rapid

0.5

2

2

3.5

Rapid

Ultra Rapid

4

open

To identify the burners on your hob, refer to the drawings in point “ 5.8 Hob burner
layout”.