beautypg.com

Operating instructions mesures de précaution – Shark S1209 User Manual

Page 10

background image

OPERATING INSTRUCTIONS

MESURES DE PRÉCAUTION

Cleaning & Changing the Belt

IMPORTANT :

Si la trappe de succion ou le boyau se BLOQUENT, éteignez

l’aspirateur et retirez l’obstacle avant de redémarrer l’appareil.

Fig. 24

Warning: To reduce the risk of

electric shock, the power cord must

be disconnected before removing the

dust cup, HEPA-Type filter,changing the

filters or performing maintenance/trouble

shooting checks.

Occasionally the power nozzle drive

belt will require changing, the

frequency will depend upon the amount

of use your vacuum sees.

1. Turn the vacuum "Off" and unplug

from power supply.

2. Turn the vacuum upside down on a

flat level surface.

3. Using a Philips screw driver,

remove the four (4) screws that

attach the base plate to the lower

plate. (Fig. 22)

Fig. 22

1.

N’approchez pas l’aspirateur

trop près des éléments

chauffants ou des radiateurs.

5.

Lorsque vous retirez le cordon

d’alimentation de la prise

murale, tirez sur la fiche et non

pas sur le cordon.

6. Remove the belt cover (Fig. 25, #1)

7. Lift the right side of the brush bar

first and then lift the left hand side.

(Fig. 25 #2 & #3)

8. Remove the brush bar from the

power head. (Fig. 25, #4)

9. Carefully remove any belt residue

that may exist in the belt area

before replacing with a new belt.

10. Remove the worn or broken belt

from the motor drive shaft.

11 Loop the new belt first over the

motor drive shaft and then over the

agitator pulley.

6.

Ne ramassez aucun objet fumant

ou brûlant tels que les cigarettes,

allumettes ou cendres chaudes.

7.

Évitez de faire passer l’aspirateur

sur le cordon d’alimentation.

2. Avant d’insérer la fiche d’alimentation

dans la prise murale, assurez-vous

que vos mains sont sèches.

Fig. 25

12. Insert the right side of the brush

bar in first by placing the end cap

down into the slot and then do the

same with the left side. Press

firmly to make sure that each end

is completely inserted.

13. Check to make sure that the belt is

centered on the agitator pulley and

that the brush bar turns.

14. Replace the belt cover.

15. Replace the power head cover

and turn the unit over carefully.

16. Replace the lower plate, screwing

in all five (5) screws.

17. Replace the lower plate.

18. Once the lower plate is attached,

replace the base plate with the

four (4) screws.

4. After you have removed the base

plate, remove the remaining five (5)

screws from the lower plate using a

Philips screw driver. (Fig. 23)

8.

N’utilisez pas l’aspirateur sans

sa coupelle ou sans ses filtres.

3. Avant de commencer à nettoyer,

assurez-vous de retirer tout gros objet

ou tout objet coupant pouvant l’écran

de filtrage de la coupelle.

9.

Avant de commencer à nettoyer,

assurez-vous de retirer tout gros

objet ou tout objet coupant

pouvant endommager

l’aspirateur.

Base Plate

Lower Plate

Fig. 23

4.

Tenez toutes les parties du corps,

les doigts, les cheveux et les

vêtements lâches éloignés des

ouvertures, du batteur rotatif et des

autres pièces mobiles.

5. With the unit still lying down, turn

the unit over and lift the power head

cover starting from the back of the

power head. (Fig. 24)

8

25