STOW G-4.5R — CONTROLS AND INDICATORS

14. Choke Lever – Used for starting the engine.

Close

the

choke lever when starting a cold engine or in cold weather
conditions. The choke enriches the fuel mixture.

Open

the

choke lever if starting a warm engine or in warm weather
conditions.

15. Fuel Cock Lever – Turn this lever

downward

to

start

(down)the flow of fuel to the carburetor. Turn

upward

to

stop (

up

)

the flow of fuel.

16. Throttle Lever – Used to adjust engine RPM speed. This

unit is set at the factory and is not adjustable.

17. Engine – This generator uses a 9.0 HP ROBIN air-

cooled, 4-stroke , single cylinder, overhead camshaft
gasoline engine. Engine uses unleaded fuel.

18. Recoil Starter (Pull Rope) – Used for manual-starting of

the engine. Pull the starter grip until resistance is felt, then
pull briskly and smoothly.

19. Air Cleaner – Prevents dirt and other debris from entering

the fuel system. Remove wing-nut on top of air filter
cannister to gain access to filter element. NEVER run the
engine without an air cleaner.

20. Muffler/Heat Shield – Used to reduce noise and emissions.

NEVER touch this

heat shield

when the generator is in

use. Always allow time for the generator to cool down before
performing maintenance.

21. Oil Dipstick/ Filler Cap– Remove the filler cap dipstick

when checking the engine oil level. Add engine oil through
this filler port. See Table 4 for recommended type engine
oil.

22. Oil Drain Plug – Remove this plug to drain engine oil from

the crankcase.

23. Spark Plug – Provides spark to the ignition system. Set

spark plug gap to 0.6 - 0.7 mm (0.024 - 0.028 inch). Clean
spark plug once a week

24. Carburetor Fuel Cup – Inspect the fuel cup weekly for

water and dirt. Clean as referenced in the maintenance
section of this manual.

25. Generator Housing – Contains the rotor, rectifer field

coil assembly, aramature, bearings and other components
that make up generator asembly.

26. Fuel Gauge – Read this gauge to determine when fuel is

low

.

27. Fuel Gauge/Tank – Remove this cap to add unleaded

gasoline to the fuel tank.

Replenish

with

clean unleaded

gasoline. Make sure cap is tightened securely. DO NOT
over fill. Fuel tank capacity is 5 gallons (19 liters).

28. Lifting Bail Eye – Attach a rope or chain to this lifting eye

when lifting of the generator is required. Never stand
underneath the generator while it is being lifted. Place lifting
eye in down position when not in use.

Applies to units

with S/N 5498031 and above.

This

ROBIN

engine is equipped

with a low oil shutdown capability.
A built in sensor will automatically
turn off the engine should the oil
level fall below a safe operating

condition. Make sure the
generator is placed on level

ground. Placing the generator on level ground will ensure that
the low oil sensor will function properly.

NOTE

12. GFCI Ground – This ground connection point should be

connect to a good earth ground (ground rod).

13. Oil Alarm Indicator – This indicator will light in the event

of low oil. Applies to units with S/N 5498030 and below.