STOW G-4.5R A.C. GENERATOR — OPERATION & PARTS MANUAL — REV. #3 (03/13/06) — PAGE 15

OPERATION AND SAFETY DECALS (S/N 5498031 AND ABOVE)

Figure 2B. Operation and Safety Decals (S/N 5498031 and Above)

Before connecting this generator to any building’s
electrical system, a licensed electrician must install
an isolation (transfer) switch.

Serious injury or death may result without this
transfer switch.

WARNING!

P/N 0820610404

CONTACT

STOW PARTS DEPT.

MODEL
SERIAL NO.

Only qualified personnel should
install, use or service this
equipment.

DANGEROUS
GAS

S-4984

WARNING

Only operate machine in well ventilated
areas.

DO NOT inhale exhaust gases.

Only qualified personnel should
install, use or service this
equipment.

DANGEROUS
GAS

S-4985

DANGER

Do not touch output terminals or
internal wiring while unit is operating.

Turn off power before servicing.

Only qualified personnel should
install, use or service this
equipment.

P/N 8700611904

P/N 8700611804

ON

ON

S-3704

P/N 1980680004

FUEL COCK

CAUTION

OPERATE AT

3600 RPM ONLY

(

)

FULL THROTTLE

DAMAGE MAY RESULT IF

OPERATED AT LOWER SPEEDS

P/N 7900636004

P/N 0800628504

S-1123

P/N A92120000

1. Before starting check the oil and fuel level.
2. Switch the circuit breaker to the “OFF” position.
3. Open the fuel valve.
4. Close the choke with the choke lever.
5. Turn the operation switch to the “ON” position
6. Pull the recoil starter.
7. After the engine starts, gradually push in the choke valve.
8. Run the generator for 3-5 minutes without load.
9. Check for any abnormal noise or smell.
10.Switch the circuit breaker to the “ON” position.
11. When stopping, remove the load for 2-3 minutes before

stopping engine.

12. Turn the operation switch to the “OFF” position.
13. After the engine completely stops. Close the fuel valve.

OPERATING INSTRUCTIONS

P/N 35137

P/N A4511200402

To avoid injury,
you MUST read
and understand
operator’s manual
before using this
machine.

Ask for training
as needed.

This machine to
be operated by
qualified
personnel only.

P/N 35137

WARNING

A92120000

OPERATION

SWITCH

ON

OFF

20A

IDLE

CONTROL

ON

OFF

AC CIRCUIT

BREAKER

AC VOLTMETER

30A

20A

120/240V

120V

20A

120V

240/120V

FULL POWER

SWITCH

G-4.5R

P/N A4561000203