1100 Old Honeycutt Road, Fuquay-Varina, NC 27526
(919) 762-1000 www.southbendnc.com
Models:
Form KSLG Rev 1 (November/2010)
KSLG-20
KSLG-40
KSLG-60
INTENDED FOR COMMERCIAL USE ONLY.
NOT FOR HOUSEHOLD USE
.
SERVICE CONNECTIONS
– Supply gas through 3/4” pipe. A gas shut-off valve must be installed in supply piping convenient and adjacent to appliance
– Unless other wise specified, Field Wire Electrical Connection to be 120 Volts, 60 Hertz, single phase with grounding wire. Unit furnished
with 6’ cord and 3 prong plug. Total maximum amps 4.0.
M
odel
C
apaCity
U
nits
a
B
C
d
e
F
G
H
J
K
l
KSLG-20
20 gallons
(76 liters)
in
(mm)
20”
(508)
31.25”
(794)
40”
(1016)
32”
(813)
3”
(76)
19”
(483)
64”
(1626)
24”
(610)
30.5”
(775)
6”
(152)
18.25”
(464)
KSLG-40
40 gallons
(152 liters)
in
(mm)
26”
(660)
35.5”
(902)
44”
(1118)
38.5”
(978)
2”
(51)
19”
(483)
72”
(1829)
29”
(737)
35”
(889)
6”
(152)
22”
(559)
KSLG-60
60 gallons
(227 liters)
in
(mm)
30”
(762)
40”
(1016)
49.5”
(1257)
42”
(1016)
2.5”
(63)
21.5”
(546)
85”
(2159)
35”
(889)
39”
(991)
8”
(203)
24.62”
(625)
DIMENSIONS
M
odel
G
as
s
Upply
M
iniMUM
C
learanCe
*
BtU/Hr.
kW/HR.
s
Upply
p
ipe
p
ressUre
(W.C.)
KSLG-20/40
100,000
29.3
Natural
6”-14” (152-356 mm)
Propane
11”-14” (279-356 mm)
Sides
6” [152 mm]
KSLG-60
130,000
38.1
Back
2” [51 mm]
M
odel
s
HippinG
W
eiGHt
KSLG-20
440 lbs. [200 kg]
KSLG-40
600 lbs. [272 kg]
KSLG-60
720 lbs. [327 kg]