8
3 DISPLAY
Can indicate the program which will begin and the boiler/Tank
temperature.
In case of anomalies an error code will be indicated, for example
“E 1”
- Boiler temperature anomaly
- Tank temperature anomaly
- Tank loading anomaly
- Tank draining anomaly
- Boiler anomaly
Start button
Initiates the program shown on the display
L3
Bicolor led indictor
This led indicates the state of the machine
• Green indicates the machine is ready for a new program
• Red indicates the machine is busy with an operation
• Yellow indicates a break after Tank draining
MACHINE CONFIGURATION PARAMETERS (Intended for technical personnel, not the user)
Parameter Description
Range
Preset
P0
Drain cycle time
1-5’
1
P1 Boiler
temperature
60-95°C
82
P2 Tank
temperature
40-65°C
55
P3 Rinse
duration
10-40’’
13
P4
BOILER STOP option
YES/NO
1 YES
P5
Brief wash time
60-90
60
P6
Drain with overflow option
YES/NO
1 YES
P7
Cold rinse option
YES/NO
0 NO
P8
Regeneration option
YES/NO
1 YES
P9
Maximum water load duration
1-10’
10
P10
H2O Hardness (to be set by the user based on water hardness)
35
15
P11
Machine type
4
4
P12
Wash number counter
YES
1 YES
PARAMETER FUNCTION WITH MACHINE ON
Upon first installation it is possible to perform a series of operations which allow for the personalization of the
dishwasher based on the user’s necessities, as well as a test cycle which quickly checks the functionality of all of
the components. To perform these operations it is necessary to set the machine to “programming mode” as
described hereafter
‐
Shut the machine off by pressing
‐ Simultaneously
press and
until P0 appears on the display
‐ With
the button (ahead) and the
button (back) select the programs
‐
Once the parameter to modify has been identified, keep the
button pressed and modify the required
setting with the “ahead”
and “back”
buttons
‐
Once the setting has been correctly modified, release the
button
‐
When finished with the settings turn the machine off and on again by pressing
Note: always turn on the DRAIN PUMP function in machines with Air Tank or Break Tank even if absent.
IN PARAMETERIZATION MODE, IF NO BUTTON IS PRESSED WITHIN 30 SECONDS THE KEYBOARD SHUTS
DOWN AND RETURNS TO ITS OFF STATE.