Smeg CW400RSD User Manual
Page 7
6
ZERO CROSSING : The relay which powers the Tank’s electrical resistance is equipped with the “ zero crossing “
function which synchronizes the switching of this relay, both in closing and in opening, with the voltage supply’s
passing to zero both for 50 Hz and 60 Hz frequencies. In this manner the relay’s contacts usage is significantly
reduced.
CONNECTION SCHEME
Clamp
Connection for model. CWC500R
Connection for models CW400RSD – CW400R
1 – 2
CONTROL UNIT POWER SUPPLY, 230 VAC
CONTROL UNIT POWER SUPPLY, 230 VAC
3 – 4
BOILER TEMPERATURE SENSOR
BOILER TEMPERATURE SENSOR
5 – 6
TANK TEMPERATURE SENSOR
TANK TEMPERATURE SENSOR
10
BREAK-TANK PRESSOSTAT
BREAK-TANK PRESSOSTAT
11
Reserve input
SALT CONTAINER SENSOR
12
MICRO HOOD
MICRO DOOR
13
TANK PRESSOSTAT, closed over level
TANK PRESSOSTAT, closed over level
14
COMMON INPUTS
COMMON INPUTS
15
BOILER RESISTANCE REMOTE CONTROL SWITCH COIL
BOILER RESISTANCE REMOTE CONTROL SWITCH COIL
16
TANK RESISTANCE, max. 10 Amp.
TANK RESISTANCE, max. 10 Amp.
17 -
REGENERATION
ELECTROVALVE
18 -
COLD
RINSE
ELECTROVALVE
18 B.TANK
RINSE PUMP (MACHINE TYPE 4)
RINSE PUMP (MACHINE TYPE 4)
19
WASH PUMP ( max. 1 HP )
WASH PUMP ( max. 1 HP )
20
RINSE ELECTROVALVE + PRESSURE INCREASE PUMP
RINSE ELECTROVALVE + PRESSURE INCREASE PUMP
21
DRAIN PUMP ( max. 0.75 HP ) Optional
DRAIN PUMP ( max. 0.75 HP ) Optional
22
OUTPUT POWER SUPPLIES, 230 VAC phase
OUTPUT POWER SUPPLIES, 230 VAC phase