ZERO CROSSING : The relay which powers the Tank’s electrical resistance is equipped with the “ zero crossing “
function which synchronizes the switching of this relay, both in closing and in opening, with the voltage supply’s
passing to zero both for 50 Hz and 60 Hz frequencies. In this manner the relay’s contacts usage is significantly
reduced.

CONNECTION SCHEME

Clamp

Connection for model. CWC500R

Connection for models CW400RSD – CW400R

1 – 2

CONTROL UNIT POWER SUPPLY, 230 VAC

CONTROL UNIT POWER SUPPLY, 230 VAC

3 – 4

BOILER TEMPERATURE SENSOR

BOILER TEMPERATURE SENSOR

5 – 6

TANK TEMPERATURE SENSOR

TANK TEMPERATURE SENSOR

10

BREAK-TANK PRESSOSTAT

BREAK-TANK PRESSOSTAT

11

Reserve input

SALT CONTAINER SENSOR

12

MICRO HOOD

MICRO DOOR

13

TANK PRESSOSTAT, closed over level

TANK PRESSOSTAT, closed over level

14

COMMON INPUTS

COMMON INPUTS

15

BOILER RESISTANCE REMOTE CONTROL SWITCH COIL

BOILER RESISTANCE REMOTE CONTROL SWITCH COIL

16

TANK RESISTANCE, max. 10 Amp.

TANK RESISTANCE, max. 10 Amp.

17 -

REGENERATION

ELECTROVALVE

18 -

COLD

RINSE

ELECTROVALVE

18 B.TANK

RINSE PUMP (MACHINE TYPE 4)

RINSE PUMP (MACHINE TYPE 4)

19

WASH PUMP ( max. 1 HP )

WASH PUMP ( max. 1 HP )

20

RINSE ELECTROVALVE + PRESSURE INCREASE PUMP

RINSE ELECTROVALVE + PRESSURE INCREASE PUMP

21

DRAIN PUMP ( max. 0.75 HP ) Optional

DRAIN PUMP ( max. 0.75 HP ) Optional

22

OUTPUT POWER SUPPLIES, 230 VAC phase

OUTPUT POWER SUPPLIES, 230 VAC phase