12 SCREEN DISPLAYED ANOMALIES (USER)
The machine is capable of signaling a series of malfunctions on the display.
If the problem persists after having turned the machine off and then on again, act as indicated below:
E1
Boiler sensor malfunction
Consult with the Technical Assistance Service
E2
Tank sensor malfunction
Consult with the Technical Assistance Service
E3
Water loading timeout ( the water loading duration
has exceeded the set time )
Verify that the water supply faucet is open, the
dynamic pressure of the supply and the
cleanliness of the water input filter. If the problem
persists consult with the Technical Assistance
Service.
E6
Draining anomaly. At the end of the draining phase
the CPU still detects water in the Tank. This may
be due to: Drain pump malfunction (if present),
drain tube blockage, Tank Pressostat malfunction,
drain cycle time set too low, overflow inserted in
the Tank
Verify the cleanliness of the filters and that the
drain tube is not blocked, bent or crushed.
Verify that the drain pump is not blocked by a
foreign object: act as indicated in point “10.2
Periodic Checks”.
If the problem persists consult with the Technical
Assistance Service.
E7
30 minute Tank timeout
Consult with the Technical Assistance Service
E8
15 minute boiler timeout