beautypg.com

12 screen displayed anomalies (user) – Smeg CW400RSD User Manual

Page 21

background image

 

20

12 SCREEN DISPLAYED ANOMALIES (USER)

 

The machine is capable of signaling a series of malfunctions on the display.
If the problem persists after having turned the machine off and then on again, act as indicated below:

 

E1

Boiler sensor malfunction

Consult with the Technical Assistance Service

E2

Tank sensor malfunction

Consult with the Technical Assistance Service

E3

Water loading timeout ( the water loading duration
has exceeded the set time )

Verify that the water supply faucet is open, the
dynamic pressure of the supply and the
cleanliness of the water input filter. If the problem
persists consult with the Technical Assistance
Service.

E6

Draining anomaly. At the end of the draining phase
the CPU still detects water in the Tank. This may
be due to: Drain pump malfunction (if present),
drain tube blockage, Tank Pressostat malfunction,
drain cycle time set too low, overflow inserted in
the Tank

Verify the cleanliness of the filters and that the
drain tube is not blocked, bent or crushed.
Verify that the drain pump is not blocked by a
foreign object: act as indicated in point “10.2
Periodic Checks”.
If the problem persists consult with the Technical
Assistance Service.

E7

30 minute Tank timeout

Consult with the Technical Assistance Service

E8

15 minute boiler timeout

 

This manual is related to the following products: