Unit Not Heating Properly (No Gas Error)

Unit Not Heating Properly (No Gas Error)

Disconnect power. Remove control panel thumbscrew and

slide control panel out, Reconnect power.

Start unit. Check gas supply pressure. (There is an inlet

pressure tap on the gas combination valve that can be used

for this purpose.) Supply pressure should be > 7" W.C. for

natural gas and > 11" W.C. for propane.

With door

closed, do main

burners come

on?

Go to page 29,

Blower Not

Running Properly.

Does

blower come

on?

Yes

Yes

Place unit in oven

mode at 200°F.

Open door.

Depress door switch.

Check gas manifold pressure.

(There is a tap on the gas

combination valve for this

purpose.) Pressure should be

approximately 4.0" W.C. for

natural gas or approximately

10.0" W.C. for propane.

Is voltage

approximately 24

volts?

Replace control board.

Replace gas valve.

No

Yes

Remove front lower panel and burner box cover.

Place unit in oven

mode at 500

°F.

Close door.

No

Check voltage between

HI terminal and C

terminal of gas valve.

No

Does gas

pressure meet

specifications?

Check gas

valve wiring.

Replace gas

combination valve.

No

Yes