Control/address settings, Control switch, Address switch – Sanyo MEGAPIXEL VCC-HD5400 User Manual
Page 12
11
Control/Address Settings
When you connect the camera to a controller, it is necessary to configure the interface board control
switch and address switch.
Control switch
This is used to configure transmission rate and protocol, etc.
Switches 2 and 3 are not used.
Settings in bold typeface in the table below show the factory default
configurations.
•
•
Baud Rate
Configure the transmission rate of connected devices to the transmission
rate of the camera.
Transmission Rate
Switch 6
Switch 5
2400
OFF
OFF
4800
ON
OFF
9600
OFF
ON
19200
ON
ON
When protocol is set to “PELCO”, set to 2400.
Protocol
Select the protocol for controlling the camera.
Protocol
Switch 4
Corresponding Protocol
SSP (SANYO)
OFF
Automatic switching between Sanyo SSP and high speed SSP
PELCO
ON
Automatic switching between PELCO-D and PELCO-P
Terminator
When you connect multiple cameras, set the terminator setting (Switch 1) of the final device to “ON”
and all other devices to “OFF”.
Address switch
If you use the RS485 communication mode, assign a unique address (camera No.) to each camera.
ON
1
2
3
4
5
6
7
8
Configure the address by setting the dip switches to “ON” and “OFF”.
For further information, refer to the “Address Settings Table” on
the next page.
■
■
ON
6
5
4
3
2
1
ON
6
5
4
3
2
1