Instruction for the installer, G30/g31, Mbar – Smeg VA91XVG User Manual
Page 7: Natural gas
Instruction for the installer
9
3.2 Burner and nozzle characteristics table (60 cm. models)
Burner
Rated
heating
capacity
(kW)
LPG
–
G30/G31
28/37
mbar
Nozzle
diameter
1/100 mm
By-pass
mm
1/100
Reduced
flowrate
(W)
Flowrate
g/h G30
Flowrate
g/h G31
Auxiliary
1.0
50
30
350
73 71
Semi-rapid
1.75
65
33
450
127 125
Triple crown
3.2
91
65
1500
233 229
Oven
3.2
87
48
850
233 229
Burner
Rated
heating
capacity
(kW)
NATURAL GAS –
G20
20
mbar
Nozzle diameter
1/100 mm
Reduced Flowrate
(W)
Auxiliary
1.0
72
350
Semi-rapid
1.75
97
450
Triple crown
3.5
133
1500
Oven
3.2
130
850
This manual is related to the following products: