INSTALLATION AND EXTERNAL CONNECTION
Output Connection
- If the door lock is in POWER FAIL SAFE mode: (Door 1: Relay #1, Door 2: Relay #3)
Connect the COM line of the Door Lock relay to DC +12V.
Connect the plus (+) line of the Door Lock to the Normal Close (NC) line of the Door Lock relay.
Connect the minus (-) line of the Door Lock to GND (-).
- If the Door Lock is in POWER FAIL SECURE mode: (Door 1: Relay #1, Door 2: Relay #3)
Connect the COM line of the relay to DC +12V.
Connect the plus (+) line of the Door Lock to the Normal Open (NO) line of the Door Lock relay.
Connect the minus (-) line of the Door Lock to GND (-).
Alarm Device Connection (Door 1 Alarm: Relay #2, Door 2 Alarm: Relay #4)
Connect the COM line of the alarm device relay to DC +12V.
Connect the plus (+) line of the alarm device to the NO line of the alarm device relay.
Connect the minus (-) line of the alarm device to GND (-).
Door Number
Door Lock
Alarm Device
Note
Two Door Control
1
Relay Output #1
Relay Output #2
2
Relay Output #3
Relay Output #4
Three Door Control
1
Relay Output #1
Relay Output #2
2
Relay Output #8
Relay Output #9
I/O Board
3
Relay Output #10
Relay Output #11
I/O Board
Four Door Control
1
Relay Output #1
Relay Output #2
2
Relay Output #3
Relay Output #4
3
Relay Output #8
Relay Output #9
I/O Board
4
Relay Output #10
Relay Output #11
I/O Board
1.
2.
3.
1.
2.
3.
1.
2.
3.
Door Lock
POWER FAIL SAFE
POWER FAIL SECURE
GND
Alarm Device
DC +12V
GND
NC
COM
COM
NO