Installation and external connection, Input connection – Samsung SSA-P401 User Manual
Page 16
16_
installation and external connection
installation and external connection
Input Connection
- Exit Button Connection (Input #1, Input #3)
Connect one line of the Exit button to an input port (Door 1: Input #1, Door 2: Input #3) of the Exit button.
Connect the other line of the Exit button to GND (-).
- Door Sensor Connection (Input #2, Input #4)
Connect one line (COM) of the door open/close sensor to the input port (Door 1: Input #2, Door 2: Input #4) of
the door sensor.
Connect the other line (NC) of the door sensor to GND (-).
Door Number
Exit Button
Door Open Sensor
Note
Two Door Control
1
Input #1
Input #2
2
Input #3
Input #4
Three Door Control
1
Input #1
Input #2
2
Input #8
Input #9
I/O Board
3
Input #10
Input #11
I/O Board
Four Door Control
1
Input #1
Input #2
2
Input #3
Input #4
3
Input #8
Input #9
I/O Board
4
Input #10
Input #11
I/O Board
1.
2.
1.
2.
PUSH
PUSH
Door Open Sensor
Exit Button
Door Open Sensor
Exit Button
GND
Input #7
GND
Input #6
GND
Input #5
GND
Input #4
GND
Input #3
GND
Input #2
GND
Input #1