4.3.10 Power saving control (PSC)

The power saving control message uses the following type field octet:

Type:

Bit 1

Bit 2

Bit 3

Bit 4

Bit 5

Bit 6

Bit 7

Bit 8

1 C/R

0

0

0

0 1 0



C/R bit: Indicates whether the sequence is a command or a response.

Length:

The length byte contains the value 0 (no value octet) or 1 (one value octet).


Value octet (Length=1)

Bit 1

Bit 2

Bit 3

Bit 4

Bit 5

Bit 6

Bit 7

Bit 8

P1 P2 P3 P4 0 0 0 0


The P-bits are defining the parameter value.

In commands:

Bit 1

Bit 2

Bit 3

Bit 4

Description

0

0

0

0

Switches to the same mode as without a
value octet

1 0 0 0 Switches

into

full

functionality

mode,

like

AT+CFUN=1

0

1

0

0

Switches into NON-CYCLIC SLEEP mode,
like AT+CFUN=0

1

1

0

0

Switches into CYCLIC SLEEP mode, like
AT+CFUN=5

0

0

1

0

Switches into CYCLIC SLEEP mode, like
AT+CFUN=6

1 0 1 0 Switches

off,

like

AT^SMSO

0 1 1 0 Resets,

like

AT+CFUN=1,1

1

1

1

0

Switches into CYCLIC SLEEP mode, like
AT+CFUN=7

0

0

0

1

Switches into CYCLIC SLEEP mode, like
AT+CFUN=8


All wake up events and details of the CYCLIC and NON-CYCLIC SLEEP mode are specified
in [2].

In responses:

Bit 1

Bit 2

Bit 3

Bit 4

Description

0 0 0 0 Failure
1 0 0 0 Success


Figure 12: Power Saving Control (PSC)