Power saving control (psc), Figure 12: power saving control (psc), Chapter 4.3.10 – Siemens Mux_guide_v06 User Manual
Page 30
Multiplexer User's Guide
Confidential / Released
s
m
o
b
i
l
e
Mux_guide_v06
Page 30 of 36
30.06.2004
4.3.10 Power saving control (PSC)
The power saving control message uses the following type field octet:
Type:
Bit 1
Bit 2
Bit 3
Bit 4
Bit 5
Bit 6
Bit 7
Bit 8
1 C/R
0
0
0
0 1 0
C/R bit: Indicates whether the sequence is a command or a response.
Length:
The length byte contains the value 0 (no value octet) or 1 (one value octet).
Value octet (Length=1)
Bit 1
Bit 2
Bit 3
Bit 4
Bit 5
Bit 6
Bit 7
Bit 8
P1 P2 P3 P4 0 0 0 0
The P-bits are defining the parameter value.
In commands:
Bit 1
Bit 2
Bit 3
Bit 4
Description
0
0
0
0
Switches to the same mode as without a
value octet
1 0 0 0 Switches
into
full
functionality
mode,
like
AT+CFUN=1
0
1
0
0
Switches into NON-CYCLIC SLEEP mode,
like AT+CFUN=0
1
1
0
0
Switches into CYCLIC SLEEP mode, like
AT+CFUN=5
0
0
1
0
Switches into CYCLIC SLEEP mode, like
AT+CFUN=6
1 0 1 0 Switches
off,
like
AT^SMSO
0 1 1 0 Resets,
like
AT+CFUN=1,1
1
1
1
0
Switches into CYCLIC SLEEP mode, like
AT+CFUN=7
0
0
0
1
Switches into CYCLIC SLEEP mode, like
AT+CFUN=8
All wake up events and details of the CYCLIC and NON-CYCLIC SLEEP mode are specified
in [2].
In responses:
Bit 1
Bit 2
Bit 3
Bit 4
Description
0 0 0 0 Failure
1 0 0 0 Success