beautypg.com

Dlc release, Close-down procedure, Multiplexer control channel – Siemens Mux_guide_v06 User Manual

Page 26: Customer µc gsm engine

background image

Multiplexer User's Guide
Confidential / Released

s

m

o

b

i

l

e

Mux_guide_v06

Page 26 of 36

30.06.2004

4.3.4 DLC release

No provision is made to repeat the request if no response is received.

Customer

µC

GSM

engine

DISC: P = 1

UA: F = 1
DM: F = 1

responding station is
already disconnected

Figure 9: DLC release

4.3.5 Close-down procedure

To close down the multiplexer follow these two steps:
• First, disconnect all DLCIs by sending the DLCI Release command within the multiplexer

control channel frame (as described in section 4.3.6).

• Finally, close down the multiplexer control channel (DLCI = 0) by sending the multiplexer

close down command CLD (see section 4.3.7). After this, both the “initiating station” and
the “responding station” revert to AT command mode.


Before closing the multiplexer make sure that there is no ongoing activity on one of the
channels. For example, check that voice, CSD or GPRS connections have ended and wait
until all pending AT command responses are received.

4.3.6 Multiplexer control channel

DLCI = 0

Type

1 Octet

Length

n Octets

Value 1

1 Octet

Value 2

1 Octet

.....

Value n

1 Octet

Information Field

Figure 10: Multiplexer control channel


The commands are sent as information in the multiplexer control channel frame.

Type field:

Bit 1

Bit 2

Bit 3

Bit 4

Bit 5

Bit 6

Bit 7

Bit 8

EA

C/R T1 T2 T3 T4 T5 T6

EA bit:

Extension bit.
In the last octet of the sequence the EA bit = 1, otherwise = 0.
If there is only on octet, EA bit = 1 is set.

C/R bit:

Indicates whether the sequence is a command or a response.

T-bits: