beautypg.com

Accessories – Siemens WTXD5522UC User Manual

Page 9

background image

9

All joints should be tight to avoid leaks.

The male end of each duct section

must point away from the dryer.
Whether connecting to an existing

venting system or a new venting

system, make sure that all ducting is

clean and free of lint.
The maximum permitted length for both

rigid and flexible metal duct is shown in

the table below.

Number of
90° Turns
or Elbows

Rigid Duct

Flexible Duct

0

66 ft.
(2011 cm)

45 ft.
(1372 cm)

1

56 ft.
(1707 cm)

36 ft.
(1097 cm)

2

48 ft.
(1463 cm)

29 ft.
(884 cm)

3

39 ft.
(1189 cm)

22 ft.
(671 cm)

4

30 ft.
(914 cm)

16 ft.
(488 cm)

Note:

Side and bottom exhaust installations

have a 90° turn inside the dryer. To

determine maximum exhaust length,

add one 90° turn to the chart.
More than two 90

°

turns are not

recommended. For best performance,

separate all turns by at least 4 ft. of

straight duct, including distance

between last turn and exhaust hood.

Exhaust vent hood

The exhaust duct must end with an

approved exhaust vent hood with

swing out damper(s). DO NOT

use an

exhaust vent hood with magnetic

latches.
To avoid exhaust restriction, the outlet

must be a minimum of 12 inches (30

cm) above ground level or any other

obstructing surface.

Required parts

The parts required for the exhaust air

system (elbows, lines, exhaust air

outlets) are not included in standard

delivery of the dryer.

Accessories

The accessory kits can be obtained

from customer service or your local

dealer. Please follow the installation

instructions supplied with the kits.

Side exhaust kit

part no.

WZ 20365

Note:

The maximum permitted number of 90°

elbows (including this side exhaust kit)

is four!

i

Special tool for cutting the hole in
preparing the side panel is

required. Contact your local

dealer!

Propane - Gas Kit

part no.

WZ 20380

The parts required for conversion to

Propane gas can be obtained from

your local dealer.
If you have a propane gas dryer and

need to convert it to natural gas,

(Service Kit 496297), please consult

your customer service agent for

assistance.
Note:

Dryer must be checked for proper

operation whenever the gas

connections have been broken.

Bottom exhaust kit

part no.

WZ 20370

Note:

The maximum permitted number of 90°

elbows (including this side exhaust kit)

is four!

Dryer rack

part no.

WZ 20390

Use the dryer rack to dry washable

woolen textiles (e.g. sweaters) and

shoes.

Left hinge kit

part no.

WZ 20360

This manual is related to the following products: