Warning, Gas connection – Siemens WTXD5522UC User Manual
Page 7

7
d
WARNING
d
The dryer must only be connected
to an individual branch circuit via a
socket which has been properly
installed and grounded.
The household electrical voltage must
correspond to the voltage specification
on the dryer (rating plate).
You will find the rating plate on the
inside of the front panel.
Connection specifications as well as
the electrical requirements are
stipulated on the appliance nameplate.
Make sure that:
-
the power cord plug fits into the
socket.
-
the power cord is acceptable for
use in this application.
-
the grounding system is properly
installed.
The power cord may be replaced by an
electrician only.
Replacement power cords are available
from Customer Service.
Volts
Hertz
Amperes
Watts
110-120
60
9
1080
Gas connection
d
WARNING
d
TO AVOID Explosion hazard!
Use a new AGA or CSA approved
gas supply line.
Install a shutĆoff valve.
Securely tighten all gas
connections.
Have a qualified person make sure
gas pressure does not exceed
14 in. W.C./ 3.49 kPa/ 0.506 psig.
(Natural and Propane Gas).
Example of a qualified person
include:
-
licensed heating personnel,
-
authorized gas supplier personnel,
-
authorized service personnel.
Failure to do can result in explosion
or fire.
Risk of death or injury!
All gas line connections must be
tested for leaks prior to appliance
operation. Apply soapy water to gas
line connections and check for
formation of new bubbles. Bubbles
indicate leak!
When installing the gas supply to the
gas dryer inlet pipe, do not exceed 310
lbf in (35 Nm).
d
WARNING
d
Never use an open flame to test for
gas leaks.
Gas type
This gas dryer when equipped for use
with NATURAL GAS, will employ an
orifice size 46 and have a gas outlet
pressure of 3.5 in. W.C. This gas dryer
when equipped for use with PROPANE
GAS, will employ an orifice size of 1.21
mm, and have a gas outlet pressure of
11 in. W.C.
Your dryer must have the correct valve
for the type of gas in your home. Valve
information is located on the rating
plate behind the door below the drum.
If the ratingĆplate information does not
agree with the type of gas available,
contact your dealer or our customer
service team (see page 22).
Gas supply line
1
/
2
" I.D. pipe is recommended.
3
/
8
" approved tubing is acceptable for
lengths under 20 ft (6.1 m) if local
codes and gas supplier permit.
Must include
1
/
8
" NPT plugged
tapping, immediately upstream of the
gas connection.
A shut off valve must be included:
-
USA:
An individual manual shutĆoff valve
must be installed within 6 ft (1.8 m)
of the dryer in accordance with the
National Fuel Gas Code, ANSI
Z223.1.
-
Canada:
An individual manual shutĆoff valve
must be installed in accordance
with the B149, Installation Codes,
CAN/CSA B149.1 and CAN/CSA
B149.2. It is recommended that an
individual manual shutĆoff valve be
installed within 6 ft (1.8 m) of the
dryer.
1111
5
1
2
3
4
1 ć
1
/
2
" NPT gas supply line
2 ć Gas shutĆoff valve
3 ć
1
/
8
" NPT plugged tapping
4 ć
3
/
8
" pipe to flare adapter fitting
5 ć
3
/
8
" flexible gas connector (to the dryer)
The shutĆoff valve should be easy to
reach for opening and closing.
Note:
The dryer must be checked for proper
operation whenever the gas
connections have been broken.