Samsung SCX-5112 User Manual
Page 99

M
AINTENANCE
7.10
5
Reinstall the toner cartridge, then lock the lever.
N
OTE
:
If your machine automatically recognises the replaced
cartridge, you can skip following 6 and 7 steps.
6
Close the front cover and the side cover. The LCD displays
“NEW DRUM? 1.YES 2.NO”.
7
Select “YES” by pressing 1. The product returns to Standby
mode.
If the drum cartridge does not work properly and it is required
to replace with a new one before “DRUM WARNING” or “DRUM
EMPTY” appears on the display, replace the drum cartridge as
described above then take the following steps to reset the drum
counter:
1
Press Menu/Exit then Maintenance from the one-touch
dial keypad.
SCX-5112 users should press Menu then press or until
“MAINTENANCE” appears on the top line.
2
Use
or
until “NEW DRUM” appears on the bottom line
of the display, and press Mode/Enter (Enter on SCX-
5112).
3
“NEW DRUM UNIT?” appears on the top line and “1.YES
2.NO” appears on the bottom line. Press 1 to select “1.YES.”
N
OTE
:
If you do not reset the counter, “DRUM WARNING” or
“DRUM ENPTY” may appear before the time is up.