beautypg.com

1 test for prominent discrete tones (pdts), 11 electromagnetic immunity, 12 reliability – Seagate BARRACUDA ST1500DL003 User Manual

Page 20: Test for prominent discrete tones (pdts), Electromagnetic immunity, Reliability 2.12.1

background image

20

Barracuda Green SATA Product Manual, Rev. D

Drive Specifications

www.seagate.com

2.10.1 Test for Prominent Discrete Tones (PDTs)

Seagate follows the ECMA-74 standards for measurement and identification of PDTs. An exception to this
process is the use of the absolute threshold of hearing. Seagate uses this threshold curve (originated in ISO 389-
7) to discern tone audibility and to compensate for the inaudible components of sound prior to computation of
tone ratios according to Annex D of the ECMA-74 standards.

2.11 Electromagnetic immunity

When properly installed in a representative host system, the drive operates without errors or degradation in
performance when subjected to the radio frequency (RF) environments defined in the following table:

2.12 Reliability

2.12.1 Annualized Failure Rate (AFR) and Mean Time Between Failures (MTBF)

The product shall achieve an Annualized Failure Rate (AFR) of 0.34% (MTBF of 0.75 million hours) when operated
in an environment of ambient air temperatures of 25

°

C. Operation at temperatures outside the specifications in

Section 2.9 may increase the product AFR (decrease MTBF). AFR and MTBF are population statistics that are not
relevant to individual units.

AFR and MTBF specifications are based on the following assumptions for desktop personal computer
environments:

• 2400 power-on-hours per year.

• 10,000 average motor start/stop cycles per year.

• Operations at nominal voltages.

Temperatures outside the specifications in Section 2.9 may reduce the product reliability.

• Normal I/O duty cycle for desktop personal computers. Operation at excessive I/O duty cycle may degrade product

reliability.

Table 4 Radio frequency environments

Test

Description

Performance

Level

Reference
standard

Electrostatic
discharge

Contact, HCP, VCP: ± 4 kV; Air: ± 8 kV

B

EN61000-4-2: 95

Radiated RF
immunity

80MHz to 1,000MHz, 3 V/m,
80% AM with 1kHz sine
900MHz, 3 V/m, 50% pulse modulation @
200Hz

A

EN61000-4-3: 96
ENV 50204: 95

Electrical fast
transient

± 1 kV on AC mains, ± 0.5 kV on external I/O

B

EN61000-4-4: 95

Surge
immunity

± 1 kV differential, ± 2 kV common, AC mains

B

EN61000-4-5: 95

Conducted RF
immunity

150kHz to 80MHz, 3 Vrms, 80% AM with 1kHz
sine

A

EN61000-4-6: 97

Voltage dips,
interrupts

0% open, 5 seconds
0% short, 5 seconds
40%, 0.10 seconds
70%, 0.01 seconds

C
C
C
B

EN61000-4-11: 94