Symptom

Possible Cause

Possible Solution

Air leaking at

whack cap area.

1. O-rings in plunger/cylinder

housing are damaged.

1. O-rings must be replaced &

operation checked.

Air leaking between

housing and hose

1. Loose screws in housing.

2. Damaged O-ring.

3. Loose air fitting.

1. Tighten screws.

2. Replace O-ring

3. Tighten air fitting & use

teflon tape.

Air leaking between

housing and cap.

1. Damaged seal.

1. Replace damaged seals.

Tool skips staples

while discharging.

1. Excessive air pressure.

2. Air leaks.

3. Dirt in nose.

4. Dirt or damage prevents

staples from moving freely.

5. Inadequate air flow to tool.

6. Worn piston O-ring or lack of

lubrication.

7. Damaged plunger/cylinder O-

rings.

8. Worn bumper.

9. Cap seal leaking.

1. Reduce air pressure to tool.

2. Tighten screws and fittings.

3. Clean nose.

4. Clean magazine and

inspect/repair damage.

5. Check fittings, hose,

compressor, and air

pressure.

6. Replace O-ring and

lubricate.

7. Replace plunger/cylinder

O-rings.

8. Replace bumper.

9. Replace cap seal.

Tool runs slowly or

has a loss of power.

1. Undersized air hose.

2. Stapler is not lubricated.

3. Broken spring in cap assembly.

4. Exhaust ports on cylinder cap

are blocked.

1. Use a larger hose.

2. Lubricate stapler.

3. Replace spring.

4. Clean or replace damaged

internal parts.

Fasteners

frequently jam the

stapler.

1. Staples are the wrong size.

2. Staples are bent or dirty.

3. Magazine or nose screws are

loose.

4. Driver or driver guide are

worn or damaged.

5. Staples are wrong angle.

1. Use correct staples.

2. Use undamaged, clean

staples.

3. Tighten magazine.

4. Replace worn or damaged

parts.

5. Use correct angle staples.

Stapler does not

fire.

1. Stapler is not lubricated.

2. Staple is jammed in magazine

or discharge area.

3. Piston shaft is damaged.

4. Air pressure too low.

1. Follow lubricating

instructions.

2. Clear stapler magazine or

discharge area.

3. Replace piston shaft.

4. Check/increase air

pressure.

Air blows out

of exhaust cap;

stapler will not

fire.

1. O-ring slipped out of groove or

damaged inside stapler.

1. Reinstall/replace suspect

O-ring; turn down air

pressure.