40
The cash register provides the electronic journal (EJ) function. By default, a maximum of 2000 lines can be
stored in memory. By decreasing the storable line numbers to 1000 lines you can expand the available number
of PLU codes to 1200.
For reading journal data, refer to “EJ REPORT READING AND RESETTING” (page 60).
EJ memory type
When this procedure is executed, EJ data is cleared, and PLU data (programming data and sales
data) are reset to the default after all data is cleared even if the same memory type is selected.
*A: 0 for EJ 1000 lines and PLU 1200 codes
1 for EJ 2000 lines and PLU 200 codes
Function parameters for EJ
* Item:
Selection:
Entry:
A
Always enter 0.
0
B
Always enter 0.
0
C
Temporary EJ printing during transaction
Disable
0
Enable*
1
D
EJ printing and clearing EJ data when
No*
0
issuing general Z1 report
Yes
1
E
PGM mode operation records type
Details*
0
Header information only
1
F
REG/MGR/VOID modes operation
Details*
0
records type
Total
1
G
Compressing printing for EJ data
No (normal size)
0
Yes (small size)*
1
H
Action when EJ memory area is full
Continue
0
Continue and warning (near full warning)* 1
Lock and warning (with near full warning)
2
s
s
68
@
*ABCDEFGH
A
To set “00000000”
s
90
@
0
A
Key operation example
s
@
90
A
*A
Electronic Journal (EJ) Programming
2