Command List

VISCA Camera-Issued Messages

ACK/Completion Messages

Command Messages

ACK

z0 4y FF

(y:Socket No.)

Completion

z0 5y FF

(y:Socket No.)

Comments

Returned when the command is accepted.

Returned when the command has been executed.

z = Device address + 8

Command Messages

Syntax Error

z0 60 02 FF

Command Buffer Full

z0 60 03 FF

Command Canceled

z0 6y 04 FF

(y:Socket No.)

No Socket

z0 6y 05 FF

(y:Socket No.)

Command Not Executable

z0 6y 41 FF

(y:Socket No.)

Comments

Returned when the command format is different or when a command with illegal

command parameters is accepted.

Indicates that two sockets are already being used (executing two commands) and the

command could not be accepted when received.

Returned when a command which is being executed in a socket specified by the

cancel command is canceled. The completion message for the command is not

returned.

Returned when no command is executed in a socket specified by the cancel

command, or when an invalid socket number is specified.

Returned when a command cannot be executed due to current conditions. For

example, when commands controlling the focus manually are received during auto

focus.

Command Message

Network Change

z0 38 FF

Comments

Issued when power is being routed to the camera, or when the VISCA device is

connected to or disconnected from the VISCA OUT jack.

Error Messages