Visca camera-issued messages, 24 command list, Ack/completion messages – Sony EVI-D100 User Manual
Page 24: Error messages network change message
24
Command List
VISCA Camera-Issued Messages
ACK/Completion Messages
Command Messages
ACK
z0 4y FF
(y:Socket No.)
Completion
z0 5y FF
(y:Socket No.)
Comments
Returned when the command is accepted.
Returned when the command has been executed.
z = Device address + 8
Command Messages
Syntax Error
z0 60 02 FF
Command Buffer Full
z0 60 03 FF
Command Canceled
z0 6y 04 FF
(y:Socket No.)
No Socket
z0 6y 05 FF
(y:Socket No.)
Command Not Executable
z0 6y 41 FF
(y:Socket No.)
Comments
Returned when the command format is different or when a command with illegal
command parameters is accepted.
Indicates that two sockets are already being used (executing two commands) and the
command could not be accepted when received.
Returned when a command which is being executed in a socket specified by the
cancel command is canceled. The completion message for the command is not
returned.
Returned when no command is executed in a socket specified by the cancel
command, or when an invalid socket number is specified.
Returned when a command cannot be executed due to current conditions. For
example, when commands controlling the focus manually are received during auto
focus.
Command Message
Network Change
z0 38 FF
Comments
Issued when power is being routed to the camera, or when the VISCA device is
connected to or disconnected from the VISCA OUT jack.
Error Messages
Network Change Message