beautypg.com

11 electromagnetic immunity, Electromagnetic immunity – Seagate BARRACUDA ES SERIAL ATA ST3750640NS User Manual

Page 28

background image

22

Barracuda ES Serial ATA Product Manual, Rev. D

2.11

Electromagnetic immunity

When properly installed in a representative host system, the drive operates without errors or degradation in
performance when subjected to the radio frequency (RF) environments defined in the following table:

Table 8:

Radio frequency environments

Test

Description

Performance level

Reference standard

Electrostatic

discharge

Contact, HCP, VCP: ± 4

kV; Air:

± 8 kV

B

EN 61000-4-2: 95

Radiated RF

immunity

80 to 1,000 MHz, 3 V/m,

80% AM with 1 kHz sine

900 MHz, 3 V/m, 50% pulse modulation @ 200 Hz

A

EN 61000-4-3: 96

ENV 50204: 95

Electrical fast

transient

± 1 kV on AC mains, ± 0.5 kV on external I/O

B

EN 61000-4-4: 95

Surge immunity

± 1 kV differential, ± 2 kV common, AC mains

B

EN 61000-4-5: 95

Conducted RF

immunity

150 kHz to 80 MHz, 3 Vrms, 80% AM with 1 kHz sine A

EN 61000-4-6: 97

Voltage dips,

interrupts

0% open, 5 seconds

0% short, 5 seconds

40%, 0.10 seconds

70%, 0.01 seconds

C

C

C

B

EN 61000-4-11: 94