Chart 1, Previous | home | next – SATO XL4xxe User Manual
Page 3
3
Barcode SATO International Pte Ltd
Electric Checks and Adjustments
Chart 1
<
previous | home | next
>
EZ Manual: XL4xxe
VR (Adjustment Level) on Main PCB
VR1
Tag Center Hole And Label Gap Sensor Level Adjustment
VR2
I-Mark Sensor Level Fine Adjustment
VR3
Ribbon Sensor Level Adjustment
VR4
Print Position Adjustment (Use Factory)
VR5
Side Hole Sensor Level Adjustment
VR6
R Corner Hole Sensor Level
VR7
Jump Hole Sensor Level Adjustment
VR8
I-Mark Sensor Level Adjustment
VR9
Tag Center Hole And Label Gap Sensor Level Fine Adjustment
VR10
R Corner Threshold Level Adjustment
VR11
Jump Hole Sensor Threshold Level Adjustment
VR12
Side Hole Sensor Threshold Level Adjustment
TP (check level) on main PCB
TP1
Side Hole Sensor Threshold Level Adjustment
TP2
R Corner Threshold Level Adjustment
TP3
Jump Hole Sensor Threshold Level
TP4
GND
VR3
VR8
VR9
VR4
VR2
VR1
VR11
VR10
VR12
TP4
TP3
TP2
TP1
VR5
VR6
VR7
B6
B5
B4
B3
B2
B1
A6
A5
A4
A3
A2
A1
Connector PIN No.
Potentiometers are located on MAIN PCB.