Troubleshooting
6
SYMPTOM
POSSIBLE CAUSE(S)
CORRECTIVE ACTION
Motor does not run
Blown fuse
Replace.
Tripped circuit
Reset.
Disconnected plug
Reinstall.
Corroded plug
Clean prongs.
Inadequate water level
Add water and test.
Tripped overload
Allow pump to cool.
Defective switch
Adjust float; replace switch.
Defective motor
Replace pump.
Float in wrong position
See Automatic Float Switch section.
Motor hums but
Impeller jammed
Unplug the pump and unclog.
flow is reduced or
Plugged check valve
Unplug the pump and unclog.
no flow
Blocked screen
Unplug the pump and clean screen.
Line leak
Unplug the pump and repair.
Worn Impeller
Unplug the pump and replace pump.
Defective motor
Unplug the pump and replace pump.
The anti-airlock hole is plugged.
Turn off the pump for a few seconds, clean out the anti-airlock hole
and restart the pump.
Runs continuously
Plugged screen
Unplug the pump and clean screen.
Defective switch
Unplug the pump and replace switch.
Float obstruction
See Automatic Float Switch section.
Hazardous Voltage. Can shock, burn or kill. Disconnect power to pump before servicing.