1.2 Technical data

6

EB 8331-1 EN

Design and principle of operation

Actuator

Type 3374

-10

-11

-15

-21

-26

-31

-36

Version with

Yoke

Ring nut

Yoke

Ring nut

Yoke

Ring nut

Fail-safe action

Without

Stem extends

Stem retracts

Rated travel

mm

30

15

30

15

Transit time for

rated travel

3)

s

240/120

120/60

240/120

120/60

Transit time in case of fail-safe

action

s

12

Actuating force

2.5 kN

Stem extends or retracts

2 kN

Stem extends

0.5 kN

Stem retracts

Power supply

207 V to 253 V, 50 Hz · 90 V to 121 V, 60 Hz

21.6 V to 27.6 V, 50 Hz

Power consumption

VA

Without positioner

With positioner

7.5/13

9.5/15

10.5/16

12.5/18

Motor switch-off

Torque-dependent

Ambient temperature range

5 to 60 °C

Storage temperature range

–20 to +70 °C

Degree of protection

IP 54 according to EN 60529, (IP 65 with cable glands

1)

)

Suspended mounting position not approved

Overvoltage category

II according to EN 60664

Design and inspection

EN 61010 Edition 3.94

Class of protection

II according to EN 61140

Electromagnetic compatibility

According to EN 61000-6-2, EN 61000-6-3 and EN 61326

Manual override

Using hex wrench · Adjustment not possible after fail-safe action has been triggered

Manual adjustment of actuators with fail-safe action only possible when power

supply is connected (see also section 4.1)

Weight, approx. kg

3.2

3.3

3.9

4.0

3.5

3.6

Materials

Housing and cover made of plastic (PPO glass fiber reinforced)

Additional electrical equipment
Limit contact

Two travel-dependent, adjustable limit contacts, perm. load 250 V AC; 3A

Resistance transmitter

2)

0 to 1000

W

, (0 to 900

W

at rated travel) max. permissible current 1 mA

1)

Cable glands M20 x 1.5 with metal nut, width across flats 23/24 mm

2)

Not for version with positioner

3)

Half the transit time possible for actuators with 50 Hz mains frequency