Scan, Priority scan, Scan priority scan – Standard Horizon Hx 350s User Manual
Page 13: 7 scan, 8 priority scan
HX350S
Owner’s Manual
page 11
4.7
SCAN
1. Select the desired channel to be scanned using the or key.
2. Press the MEM key to store the channel into the transceiver's
memory. “MEM” is displayed on the LCD.
3. Repeat steps 1 and 2 for all the channels to be scanned.
4. To delete a channel from the transceiver’s scan memory, press the MEM
key again while the memorized channel is displayed. “MEM” disappears.
5. All channels programmed remain in the transceiver’s scan memory
even if the power is turned off. See section “4.17 RESETTING THE
TRANSCEIVER’S MICROPROCESSOR” to clear all the transceiver's
scan memory.
6. Adjust the SQUELCH CONTROL knob until background noise is
eliminated.
7. To start scan, press the SCAN key. The scan proceeds from the
lowest to the highest programmed channel number and stops on
channels when a transmission is received.
8. To stop the scan, press the SCAN key.
4.8
PRIORITY SCAN
1. The following channels can be set as the priority channel; 16, 09, A,
and B. To set the priority channel, hold down the 16/9 key and press
the MEM key. The channel changes from 16 to 09 to A to B channel
with each press of the MEM key. The displayed channel is set to the
priority channel.
2. For priority scanning, hold down the SCAN key at least 1 second
during normal scanning, Scanning will proceed between the
memorized channels and the priority channel. The priority channel will
be scanned after each programmed channel.
3. For example, channels 06, 07, 08 are memorized in the transceiver’s
memory, Priority scanning will proceed in the following sequence:
4. Even when the transceiver stops and listens to the signal of a
programmed channel, the transceiver will dual watch between this
channel and the priority channel.
CH06
Priority
channel
CH07
CH08
Priority
channel
Priority
channel