beautypg.com

2 transmitter signal characteristics – Seagate Cheetah 15K.5 SAS ST373455SS User Manual

Page 71

background image

Cheetah 15K.5 SAS Product Manual, Rev. E

65

9.5.2.2

Transmitter signal characteristics

Table 16 specifies the signal requirements at the transmitter end of a TxRx connection as measured into the
zero-length test load. All specifications are based on differential measurements.

The OOB sequence is performed at signal voltage levels corresponding to the lowest supported transfer rate.
Table 16 specifies the signal characteristics.

Table 16:

Transmitter signal characteristics

Signal characteristic

a

Units

1.5 Gbps

3.0 Gbps

Skew

b

ps

20

15

Tx Off Voltage

c

mV(P-P)

< 50

< 50

Maximum rise/fall time

d

ps

273

137

Minimum rise/fall time

d

ps

67

67

Maximum transmitter output imbalance

e

%

10

10

OOB offset delta

f

mV

±

25

±

25

OOB common mode delta

g

mV

±

50

±

50

a All tests in this table shall be performed with zero-length test load shown in figure 24.
b The skew measurement shall be made at the midpoint of the transition with a repeating 0101b pattern on the physical

link. The same stable trigger, coherent to the data stream, shall be used for both the Tx+ and Tx- signals. Skew is
defined as the time difference between the means of the midpoint crossing times of the Tx+ signal and the Tx- signal.

c The transmitter off voltage is the maximum A.C. voltage measured at compliance points when the transmitter is

unpowered or transmitting D.C. idle (e.g., during idle time of an OOB signal).

d Rise/fall times are measured from 20 % to 80 % of the transition with a repeating 0101b pattern on the physical link.
e The maximum difference between the V+ and V- A.C. RMS transmitter amplitudes measured on a CJTPAT test

pattern (see 9.5.2.3.3) into the test load shown in figure 24, as a percentage of the average of the V+ and V- A.C.
RMS amplitudes.

f The maximum difference in the average differential voltage (D.C. offset) component between the burst times and the

idle times of an OOB signal.

g The maximum difference in the average of the common mode voltage between the burst times and the idle times of

an OOB signal.