Finding the Jumper «RS485 MATCH»

in the Solar Inverter

Please make sure the jumper «RS485

MATCH» is in the right position, considering

the communication interconnection you

have chosen. This jumper is on the under-

side of the interface circuit board.

Illustr.: Position of the jumper «RS485

MATCH»

Ad (6): Remote Link for up to 99 Solar

Inverters

If you wish to connect several Solar

Inverters to the remote monitoring system,

the individual Solar Inverters must be cross-

linked via RS485. The RS485 signal of the

first Solar Inverter in the row is transferred

into the interface transformer with the fol-

lowing allocation: «RS485 +» to «DATA+»

and «RS485 -» to «DATA-». Connect the

remote modem to the interface transfor-

mer. With the last Solar Inverter, the jum-

per «RS485 MATCH» must be closed. With

all other Solar Inverters, it has to be in the

open position.

To identify the individual Solar Inverters,

a clear RS485 has to be assigned to each of

them. See chapter «Setting the RS485

Address».

!